Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Upgrade of the Brookhaven 200 MeV linac

Conference ·
OSTI ID:380327
The Brookhaven 200 MeV linac serves as the injector for the AGS Booster, as well as delivering beam to the Biomedical Isotope Resource Center. During the past year, many linac systems have been upgraded to allow operation at 2.5 times higher average current (150 {mu}A). This was achieved by an increase in rep-rate from 5 to 7.5 Hz, an increase in beam current from 25 mA to 37 mA, and a slight increase in pulse width to {approximately}530 {mu}s. Additional upgrades were made to improve reliability and modernize old systems. This paper describes improvements made in the 35 keV and 750 keV beam transport, 200 MeV beam transport, rf transmission line, rf power supplies, control systems, and instrumentation.
Research Organization:
Brookhaven National Lab., Upton, NY (United States)
Sponsoring Organization:
USDOE, Washington, DC (United States)
DOE Contract Number:
AC02-76CH00016
OSTI ID:
380327
Report Number(s):
BNL--62965; CONF-9608123--34; ON: DE97000139
Country of Publication:
United States
Language:
English

Similar Records

The upgrade of the Brookhaven Linac Isotope Producer (BLIP) and the BNL Linac
Conference · Tue Dec 31 04:00:00 UTC 1996 · OSTI ID:458136

The upgrade of the Brookhaven Linac Isotope Producer (BLIP) and the BNL linac
Journal Article · Sat Feb 01 04:00:00 UTC 1997 · AIP Conference Proceedings · OSTI ID:580131

HIGH INTENSITY PERFORMANCE AND UPGRADES AT THE BROOKHAVEN AGS