Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Simultaneous SPECT and CT with an opposed dual head gamma camera system and conventional parallel hole collimators

Journal Article · · IEEE Transactions on Nuclear Science
DOI:https://doi.org/10.1109/23.531888· OSTI ID:379763
;  [1]
  1. Karolinska Hospital, Stockholm (Sweden). Dept. of Hospital Physics
All examinations aiming at quantitative assessment of activity concentrations suffer from non-uniform attenuation due to inhomogeneous tissue density in various body regions. In such applications, a combined transmission tomography with SPECT has demonstrated great clinical advantages since it allows a pixel by pixel correction for attenuation based on measured data. The authors have developed a method for transmission studies that is applicable to dual head detector systems with conventional parallel-hole collimators. A scanning line-source (Am-241) is mounted close to one camera head with its beam directed towards the other head. Two energy discrimination windows are used for each camera head. The camera-head near to the transmission source registrates SPECT-data in one window and the spill-over of scattered emission photons into the Am-window. The opposed camera registrates SPECT-data in one window and the transmission data from the Am-source in another window. Post acquisition corrections are made for differences in camera uniformity and for loss of SPECT-data due to shadowing of the field-of-view during the transverse movement of the transmission device (about 5%).
OSTI ID:
379763
Report Number(s):
CONF-951073--
Journal Information:
IEEE Transactions on Nuclear Science, Journal Name: IEEE Transactions on Nuclear Science Journal Issue: 4Pt1 Vol. 43; ISSN 0018-9499; ISSN IETNAE
Country of Publication:
United States
Language:
English

Similar Records

Fan beam collimation with off center focus for simultaneous emission/transmission SPECT in multi-camera SPECT systems
Journal Article · Sun May 01 00:00:00 EDT 1994 · Journal of Nuclear Medicine · OSTI ID:197963

Simultaneous SPECT and CT with shutter controlled radionuclide sources and parallel collimator geometry
Journal Article · Sun Aug 01 00:00:00 EDT 1993 · IEEE Transactions on Nuclear Science (Institute of Electrical and Electronics Engineers); (United States) · OSTI ID:6062332

Improved SPECT using simultaneous emission and transmission tomography
Journal Article · Fri May 01 00:00:00 EDT 1987 · J. Nucl. Med.; (United States) · OSTI ID:6354746