Simultaneous SPECT and CT with an opposed dual head gamma camera system and conventional parallel hole collimators
Journal Article
·
· IEEE Transactions on Nuclear Science
- Karolinska Hospital, Stockholm (Sweden). Dept. of Hospital Physics
All examinations aiming at quantitative assessment of activity concentrations suffer from non-uniform attenuation due to inhomogeneous tissue density in various body regions. In such applications, a combined transmission tomography with SPECT has demonstrated great clinical advantages since it allows a pixel by pixel correction for attenuation based on measured data. The authors have developed a method for transmission studies that is applicable to dual head detector systems with conventional parallel-hole collimators. A scanning line-source (Am-241) is mounted close to one camera head with its beam directed towards the other head. Two energy discrimination windows are used for each camera head. The camera-head near to the transmission source registrates SPECT-data in one window and the spill-over of scattered emission photons into the Am-window. The opposed camera registrates SPECT-data in one window and the transmission data from the Am-source in another window. Post acquisition corrections are made for differences in camera uniformity and for loss of SPECT-data due to shadowing of the field-of-view during the transverse movement of the transmission device (about 5%).
- OSTI ID:
- 379763
- Report Number(s):
- CONF-951073--
- Journal Information:
- IEEE Transactions on Nuclear Science, Journal Name: IEEE Transactions on Nuclear Science Journal Issue: 4Pt1 Vol. 43; ISSN 0018-9499; ISSN IETNAE
- Country of Publication:
- United States
- Language:
- English
Similar Records
Fan beam collimation with off center focus for simultaneous emission/transmission SPECT in multi-camera SPECT systems
Simultaneous SPECT and CT with shutter controlled radionuclide sources and parallel collimator geometry
Improved SPECT using simultaneous emission and transmission tomography
Journal Article
·
Sun May 01 00:00:00 EDT 1994
· Journal of Nuclear Medicine
·
OSTI ID:197963
Simultaneous SPECT and CT with shutter controlled radionuclide sources and parallel collimator geometry
Journal Article
·
Sun Aug 01 00:00:00 EDT 1993
· IEEE Transactions on Nuclear Science (Institute of Electrical and Electronics Engineers); (United States)
·
OSTI ID:6062332
Improved SPECT using simultaneous emission and transmission tomography
Journal Article
·
Fri May 01 00:00:00 EDT 1987
· J. Nucl. Med.; (United States)
·
OSTI ID:6354746