A field test of electret ion chambers was performed to evaluate their performance in making environmental exposure measurements at nuclear facilities. The objectives of the study were to determine electret ion chamber measurements. Three electret ion chambers were placed at each of 40 monitoring locations in the vicinity of a commercial nuclear power station during four consecutive quarters. The electret ion chamber measurements were compared to thermoluminescent dosimeter measurements made by the Nuclear Regulatory Commission and the South Carolina Department of Health and Environmental Control. Two types of comparisons were made with the high-pressure ion chamber. One used yearly average electret ion chamber measurements and instananeous high-pressure ion chamber measurements at 15 of the monitoring locations. The other involved the simultaneous exposure of five electre ion chambers measurements to thermoluminescent dosimeter measurements was 1.06. The mean ratio of electret ion chamber measurements to instantaneous and simultaneous high-pressure ion chamber measurements were 1.06 and 1.07, respectively. Electret variability, defined here as the ratio of the standard deviation to the mean, was determined for each set of three detectors. The average variability for the 160 sets of quarterly measurements, there were six outliers. Based on the results of this study, electret ion chambers appear to yield accurate measurements of environmental exposure provided that measures are taken to either minimize or correct for radon interferences and care is taken to prevent spurious discharges during handling. 12 refs., 5 figs., 9 tabs.
- Sponsoring Organization:
- USDOE
- OSTI ID:
- 379204
- Journal Information:
- Health Physics, Journal Name: Health Physics Journal Issue: 2 Vol. 66; ISSN HLTPAO; ISSN 0017-9078
- Country of Publication:
- United States
- Language:
- English
Similar Records
Fundamental study on an electret dosimeter for a surface contamination monitor
CaSo{sub 4}:Dy and LiF:Mg, Cu, P thermoluminescent dosimeters for environmental monitoring in ambient areas of a nuclear power plant
Development of an electret passive environmental radon monitor: Final report
Conference
·
Thu Oct 31 23:00:00 EST 1985
· Trans. Am. Nucl. Soc.; (United States)
·
OSTI ID:5676486
CaSo{sub 4}:Dy and LiF:Mg, Cu, P thermoluminescent dosimeters for environmental monitoring in ambient areas of a nuclear power plant
Journal Article
·
Thu Feb 29 23:00:00 EST 1996
· Health Physics
·
OSTI ID:369935
Development of an electret passive environmental radon monitor: Final report
Technical Report
·
Tue Mar 31 23:00:00 EST 1987
·
OSTI ID:6554286