The effect of pressure on annular flow pressure drop in a small pipe

Conference ·
OSTI ID:379035
New experimental data was obtained for pressure drop and entrainment for annular up-flow in a vertical pipe. The 9.5 mm. pipe has an L/D ratio of 440 to insure fully developed annular flow. The pressure ranged from 140 kPa to 660 kPa. Therefore the density ratio was varied by a factor of four approximately. This allows the investigation of the effect of pressure on the interfacial shear models. Gas superficial velocities between 25 and 126 m/s were tested. This extends the range of previous data to higher gas velocities. The data were compared with well known models for interfacial shear that represent the state of the art. Good results were obtained when the model by Asali, Hanratty and Andreussi was modified for the effect of pressure. Furthermore an equivalent model was obtained based on the mixing length theory for rough pipes. It correlates the equivalent roughness to the film thickness.
Research Organization:
Bettis Atomic Power Lab., West Mifflin, PA (United States)
Sponsoring Organization:
USDOE, Washington, DC (United States)
DOE Contract Number:
AC11-93PN38195
OSTI ID:
379035
Report Number(s):
WAPD-T--3113; CONF-9607141--1; ON: DE96013387
Country of Publication:
United States
Language:
English

Similar Records

Annular flow entrainment rate experiment in a vertical pipe
Technical Report · Sat Jun 01 00:00:00 EDT 1996 · OSTI ID:237265

Subcooled and saturated water flow boiling pressure drop in small diameter helical coils at low pressure
Journal Article · Thu May 15 00:00:00 EDT 2008 · Experimental Thermal and Fluid Science · OSTI ID:21044858

Two-phase pressure drop in lunar and Martian gravity: Experimental data and predictions
Book · Fri Dec 30 23:00:00 EST 1994 · OSTI ID:100936