Tank 241-SY-103 core sample: Interpretation of results
Technical Report
·
OSTI ID:378923
Tank 241-SY-103 accumulates and periodically releases flammable gases such as hydrogen and nitrous oxide. A full-depth core sample was taken from Tank 241-SY-103 during August and September 1994. This data was compared with similar data from Tank 241-SY-101, which exhibited gas accumulation and release behavior before it was mitigated with a mixer pump. The waste in Tank 103-SY is chemically similar to that in Tank 101-SY. Of the two tanks, Tank 103-SY has a lower density in the nonconvective layer, a lower TOC concentration, and a lower heat load.
- Research Organization:
- Westinghouse Hanford Co., Richland, WA (United States)
- Sponsoring Organization:
- USDOE, Washington, DC (United States)
- DOE Contract Number:
- AC06-87RL10930
- OSTI ID:
- 378923
- Report Number(s):
- WHC-SD-WM-TI--712; ON: DE96050190
- Country of Publication:
- United States
- Language:
- English
Similar Records
The effect of dilution on the gas retention behavior of Tank 241-SY- 103 waste
Waste behavior analysis for tank 241-SY-103
Operational experience in mitigating flammable gas releases from Hanford Site Tank 241-SY-101
Technical Report
·
Sun Dec 31 23:00:00 EST 1995
·
OSTI ID:192554
Waste behavior analysis for tank 241-SY-103
Technical Report
·
Tue Sep 27 00:00:00 EDT 1994
·
OSTI ID:10191556
Operational experience in mitigating flammable gas releases from Hanford Site Tank 241-SY-101
Conference
·
Sat Dec 31 23:00:00 EST 1994
·
OSTI ID:10123054