Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Tank 241-SY-103 core sample: Interpretation of results

Technical Report ·
OSTI ID:378923

Tank 241-SY-103 accumulates and periodically releases flammable gases such as hydrogen and nitrous oxide. A full-depth core sample was taken from Tank 241-SY-103 during August and September 1994. This data was compared with similar data from Tank 241-SY-101, which exhibited gas accumulation and release behavior before it was mitigated with a mixer pump. The waste in Tank 103-SY is chemically similar to that in Tank 101-SY. Of the two tanks, Tank 103-SY has a lower density in the nonconvective layer, a lower TOC concentration, and a lower heat load.

Research Organization:
Westinghouse Hanford Co., Richland, WA (United States)
Sponsoring Organization:
USDOE, Washington, DC (United States)
DOE Contract Number:
AC06-87RL10930
OSTI ID:
378923
Report Number(s):
WHC-SD-WM-TI--712; ON: DE96050190
Country of Publication:
United States
Language:
English

Similar Records

The effect of dilution on the gas retention behavior of Tank 241-SY- 103 waste
Technical Report · Sun Dec 31 23:00:00 EST 1995 · OSTI ID:192554

Waste behavior analysis for tank 241-SY-103
Technical Report · Tue Sep 27 00:00:00 EDT 1994 · OSTI ID:10191556

Operational experience in mitigating flammable gas releases from Hanford Site Tank 241-SY-101