Developing a cost-effective penstock safety program

Journal Article · · Hydro Review
OSTI ID:376805
In 1991 at the Control Gorge Hydro Power Plant in California, a massive penstock rupture occurred. Water at 580 feet of head poured out. The plant was down for five months, and the ensuing litigation lasted for several years. Consequently, establishing safety procedures for penstocks has taken on more importance. This article describes how to implement a penstock safety program that is simple, flexible, systematic, and cost-effective.
OSTI ID:
376805
Journal Information:
Hydro Review, Journal Name: Hydro Review Journal Issue: 3 Vol. 15; ISSN HYREE8; ISSN 0884-0385
Country of Publication:
United States
Language:
English

Similar Records

Dealing with a penstock rupture: A success story
Journal Article · Sun Aug 01 00:00:00 EDT 1993 · Hydro Review; (United States) · OSTI ID:6029436

Penstock safety: Proactive or reactive
Journal Article · Sun Mar 31 23:00:00 EST 1996 · Journal of Energy Engineering · OSTI ID:218574

Penstock productivity improved
Journal Article · Fri Sep 01 00:00:00 EDT 1989 · Independent Energy; (USA) · OSTI ID:6681511