Revisiting a runner cavitation repair job

Journal Article · · Hydro Review
OSTI ID:376804
 [1]
  1. Pennsylvania Power & Light Co., Holtwood, PA (United States)

This article reviews the efforts to repair turbine runner cavitation damage. The particular runner was originally repaired in 1990 with the application of a layer of beaded epoxy to areas of severe cavitation on the suction side of the blades on the upper runner. A year later, the runner was inspected, with no damage to the epoxy. In June of 1994, the runner was again inspected, and this and the most recent inspection shows that the epoxy coating is holding up well. The last inspection did show the beginnings on some erosion of the repair material. Based on this long-term series of inspections, maintenance recommendations are set forth.

OSTI ID:
376804
Journal Information:
Hydro Review, Journal Name: Hydro Review Journal Issue: 3 Vol. 15; ISSN HYREE8; ISSN 0884-0385
Country of Publication:
United States
Language:
English

Similar Records

Beaded epoxy applied to runner for cavitation repair
Journal Article · Tue Oct 01 00:00:00 EDT 1991 · Hydro Review; (United States) · OSTI ID:5570228

What's new in cavitation repair
Journal Article · Fri Oct 01 00:00:00 EDT 1993 · Hydro Review; (United States) · OSTI ID:5296363

Taking control of cavitation repair
Journal Article · Sun May 01 00:00:00 EDT 1994 · Hydro Review · OSTI ID:229740