Boxberg III-2 x 500 MW units: Refurbishing and environmental protection measures on the 815 T/H steam generator of works II in Boxberg Power Station
Conference
·
OSTI ID:374632
- L&C Steinmueller GmbH, Gummersbach (Germany)
The object of the upgrading measures on the steam generators is: (1) To comply with the requirements of the German antipollution law, which imposes a permissible NO{sub x} content in the flue gas of less than 200 Mg/m{sup 3} STP and a CO content of less than 250 Mg/m{sup 3} STP. (2) To increase the boiler efficiency and availability and the efficiency of the water/steam cycle.
- Research Organization:
- North Dakota Univ., Grand Forks, ND (United States)
- OSTI ID:
- 374632
- Report Number(s):
- DOE/MC/30097-5161-Pt.2; CONF-9410458-Pt.2; ON: DE96011553; TRN: 96:004422-0058
- Resource Relation:
- Conference: 2. international conference on energy and environment: transitions in East Central Europe, Prague (Czech Republic), 31 Oct - 1 Nov 1994; Other Information: PBD: Dec 1995; Related Information: Is Part Of Advanced power assessment for Czech lignite, Task 3.6, Part 2; Sondreal, E.A.; Mann, M.D.; Weber, G.W.; Young, B.C.; PB: 774 p.
- Country of Publication:
- United States
- Language:
- English
Similar Records
Development of and experience with a new generation of modern coal firing systems in a new high-efficiency combined heat and power station
Experience with a new low-NO{sub x} firing system
Study of heat exchange in a 500 MW energy unit boiler convective steam superheater with combustion of Ekibastuzsk coal
Conference
·
Thu Dec 31 00:00:00 EST 1998
·
OSTI ID:374632
+2 more
Experience with a new low-NO{sub x} firing system
Conference
·
Wed Jul 01 00:00:00 EDT 1998
·
OSTI ID:374632
Study of heat exchange in a 500 MW energy unit boiler convective steam superheater with combustion of Ekibastuzsk coal
Journal Article
·
Wed Apr 01 00:00:00 EST 1981
· Sov. Power Eng. (Engl. Transl.); (United States)
·
OSTI ID:374632