Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Shut-off of a geopressured water channel behind casing via coiled tubing utilizing a dual slurry cement system: A case history

Conference ·
OSTI ID:372328

This paper presents a case history involving a unique dual cement system to shut off a geopressured water channel behind casing utilizing coiled tubing. The channeling problem was identified and documented using water flow logging techniques. Logging indicated the lower gravel packed selective could produce salt water if perforated without eliminating the suspected water channel. Reserves did not warrant a major rig workover, making a non-rig workover via coiled tubing the only viable option to repair the well. A unique dual cement system tested on a hesitation squeeze schedule pumped through coiled tubing with extremely limited thickening time was necessary to repair the primary cement job.

OSTI ID:
372328
Report Number(s):
CONF-950433--
Country of Publication:
United States
Language:
English

Similar Records

Squeeze cement method using coiled tubing
Patent · Mon Dec 08 23:00:00 EST 1986 · OSTI ID:7229882

Improved coiled-tubing squeeze-cementing techniques at Prudhoe Bay
Journal Article · Sun Mar 31 23:00:00 EST 1991 · Journal of Petroleum Technology; (United States) · OSTI ID:5739238

Rigless multizone recompletion using a cement packer placed with coiled tubing: A case history
Journal Article · Sun Nov 30 23:00:00 EST 1997 · SPE Drilling and Completion · OSTI ID:603811