Sieve tray performances for steam stripping toluene from water in a 4-ft diameter column

Journal Article · · Industrial and Engineering Chemistry Research
DOI:https://doi.org/10.1021/ie950760w· OSTI ID:367886
; ; ;  [1]
  1. Fractionation Research, Inc., Stillwater, OK (United States)
The liquid holdup, pressure drop, and mass transfer efficiency of sieve trays for the steam stripping trace toluene from water were measured from a 4-ft column at atmospheric pressure. The measured data were then compared with predictions from often-used models. It was found that the published efficiency models whether based on distillation or stripping systems are unable to predict both the trend and value of the measured efficiency. Since the 4-ft column owned by Fractionation Research, Inc. (FRI) can be considered as an industrial-scale column, the measured efficiency provides immediate design guidelines for such services.
Sponsoring Organization:
USDOE
OSTI ID:
367886
Journal Information:
Industrial and Engineering Chemistry Research, Journal Name: Industrial and Engineering Chemistry Research Journal Issue: 8 Vol. 35; ISSN 0888-5885; ISSN IECRED
Country of Publication:
United States
Language:
English

Similar Records

Prediction of point efficiency for sieve trays in distillation
Journal Article · Wed Mar 31 23:00:00 EST 1993 · Industrial and Engineering Chemistry Research; (United States) · OSTI ID:6826772

Compact sieve-tray distillation column for ammonia-water absorption heat pump: Part 1 -- Design methodology
Conference · Thu Jul 01 00:00:00 EDT 1999 · OSTI ID:20002354

Fluid dynamics on sieve trays
Journal Article · Sun Aug 01 00:00:00 EDT 1982 · Hydrocarbon Process.; (United States) · OSTI ID:6113999