Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Radiological and toxicological consequences of a worst-case spray leak related to project W-320

Technical Report ·
DOI:https://doi.org/10.2172/362609· OSTI ID:362609
An analysis was performed of radiological and toxicological consequences of a worst-case leak from a 2-inch diameter flush connection in a pit over tank AY-102. The unmitigated (without controls) flush line spray leak assumes that the blank connector and the removable plug in the pit cover block have been removed so that the maximum system flow is directed out of the open 2-inch line vertically into the air above the pit. The mitigated (with controls) spray scenario assumes the removable plug is in place and the flow is directed against the underside of the pit cover block. The unmitigated scenario exceeded both onsite and offsite risk guidelines for an anticipated accident. For the mitigated case all consequences are well within guidelines and so no additional controls are needed beyond the existing control of having all pit covers and removable plugs in place during any waste transfer.
Research Organization:
Fluor Daniel Hanford Inc., Richland, WA (United States)
Sponsoring Organization:
USDOE Office of Environmental Restoration and Waste Management, Washington, DC (United States)
DOE Contract Number:
AC06-96RL13200
OSTI ID:
362609
Report Number(s):
HNF-SD-WM-CN--102; ON: DE99051014; BR: EW3130010
Country of Publication:
United States
Language:
English