The wall-to-suspension heat transfer in circulating fluidized beds (CFBs) operated at almost atmospheric pressure depends on the fluid mechanics immediately near the wall and on the thermal properties of the gas used. No influence of the superficial gas velocity adjusted is present. Consequently, the wall-to-suspension heat transfer coefficient in the form of the Nusselt number can be described by the Archimedes number of the gas-solid-system and the pressure drop number. The last number relates the cross-sectional average solids concentration to the solids concentration at minimum fluidization condition. However, with pressurized CFBs an influence of the superficial gas velocity on the wall-to-suspension heat transfer can be observed. Normalizing the superficial gas velocity in the form of the particle Froude number, two cases for the heat transfer in pressurized CFBs can be detected: with small particle Froude numbers (smaller than four) the same flow behavior and consequently the same heat transfer correlation is valid as it is for CFBs operated at almost atmospheric conditions; and with high particle Froude numbers (for example higher than four) the flow behavior immediately near the heat exchanger surface (CFB wall) can change. Instead of curtains of solids falling down with almost atmospheric pressure swirls of gas and solids can occur in the vicinity of the CFB wall when the static pressure is increased. With the change of the flow pattern near the CFB wall, i.e., the heat exchanger surface, a change of the heat transfer coefficient takes place. For the same Archimedes number, i.e., the same gas-solid system, and the same pressure drop number, i.e., the same cross-sectional average solids concentration, the Nusselt number, i.e., the heat transfer coefficient, increases when the flow pattern near the CFB wall changes from the curtain-type flow to that of the swirl-type flow. From experimentally obtained data in a cold running CFB a very simple correlation was obtained for the heat transfer coefficient.

OSTI ID:
357869
Report Number(s):
CONF-9705116--; ISBN 0-7918-1557-9
Country of Publication:
United States
Language:
English

Similar Records

Wall-to-suspension heat transfer in circulating fluidized beds
Book · Sat Dec 30 23:00:00 EST 1995 · OSTI ID:245037

Wall-to-bed heat transfer in circulating fluidized beds
Journal Article · Sat May 01 00:00:00 EDT 1999 · International Communications in Heat and Mass Transfer · OSTI ID:355632

Gas-solid interfacial heat transfer in circulating fluidized beds
Journal Article · Tue Nov 30 23:00:00 EST 1993 · Heat Transfer - Japanese Research; (United States) · OSTI ID:5448291