As part of a pollution prevention program, a study was conducted at Sandia National Laboratories and at the Amarillo, ''Pantex Plant'' to identify a suitable replacement solvent(s) for cleaning hardware during routine maintenance operations. Current cleaning is performed using solvents (e.g. acetone, toluene, MEK, alcohols) that are classified as Resource Conservation and Recovery Act (RCW) materials. The Environmental Protection Agency (EPA) has assigned four characteristics as the criteria for determining whether a material is identified as hazardous under RCRA: Ignitability, Corrosivity, Reactivity and Toxicity. Within the DOE and DoD sector, these solvents are used with hand wipes to clean surfaces prior to O-ring replacement, to remove decals for new labeling, to clean painted surfaces prior to reconditioning, and for other general maintenance purposes. In some cases, low level radioactive contamination during cleaning necessitates that the RCIL4 solvent-containing wipes be classified as mixed waste. To avoid using RCRA materials, cleaning candidates were sought that had a flashpoint greater than 140 F, a pH between 2.5 and 12.5, and did not fail the reactivity and toxicity criteria. Three brominated cleaners, two hydrofluoroether azeotropes and two aliphatic hydrocarbon cleaner formulations were studied as potential replacements. Cleaning efficacy, materials compatibility, corrosion and accelerated aging studies were conducted and used to screen potential candidates. Hypersolve NPB (an n-propyl bromide based formulation) consistently ranked high in removing typical contaminants for weapons applications.

Research Organization:
Sandia National Labs., Albuquerque, NM (US); Sandia National Labs., Livermore, CA (US)
Sponsoring Organization:
US Department of Energy (US)
DOE Contract Number:
AC04-94AL85000
OSTI ID:
3572
Report Number(s):
SAND99-0354C
Country of Publication:
United States
Language:
English

Similar Records

MESERAN Test Results for Elimination of Flammable Solvents in Wipe Applications at Pantex
Technical Report · Tue Mar 29 23:00:00 EST 2005 · OSTI ID:885088

Cleaning and materials compatibility test results for elimination of flammable solvents in wipe applications.
Technical Report · Wed Jun 01 00:00:00 EDT 2005 · OSTI ID:1005042

Clean room wiping liquids