Title: Sample methodology to reduce background contamination of polychlorodibenzo-dioxin/furans during stationary source sampling

Conference ·
OSTI ID:351705
;  [1];  [2]
  1. PPG Industries, Lake Charles, LA (United States)
  2. ENSR, Acton, MA (United States)

Background contamination from a variety of natural and anthropogenic sources often interferes with the accurate determination of low level polychlorodibenzo-dioxin/furan (D/F) emissions. This paper discusses the sampling methodologies adopted to determine very low levels of D/F emissions from two hazardous waste incinerator stacks operated at PPG Industries, Inc.`s Lake Charles, Louisiana complex. The stacks were evaluated under typical operating conditions for D/F using an enhanced version of USEPA Method 23. This protocol reduces the interference of background levels of D/F to the point where very low levels of emissions can be accurately demonstrated. The heightened level of precision attributable to the clean protocol should allow evaluation of any effects of minor operational changes.

OSTI ID:
351705
Report Number(s):
CONF-970677-; TRN: IM9927%%230
Resource Relation:
Conference: 90. annual meeting and exhibition of the Air and Waste Management Association, Toronto (Canada), 8-13 Jun 1997; Other Information: PBD: 1997; Related Information: Is Part Of 1997 proceedings of the Air and Waste Management Association`s 90. annual meeting and exhibition; PB: [7000] p.
Country of Publication:
United States
Language:
English