A new electrochemical noise technique for monitoring the localized corrosion of 304 stainless steel in chloride-containing solutions
Conference
·
OSTI ID:350129
- Pennsylvania State Univ., University Park, PA (United States)
- Gamty Instruments, Inc., Warminster, PA (United States)
A new electrochemical noise technique was developed to investigate metastable pitting by applying a bias potential between two nominally identical working electrodes. The current flowing between the biased working electrodes was measured with a zero resistance ammeter. Potential was measured between one working electrode and a reference electrode. These tests were conducted using 304 stainless steel working electrodes in a 0.5 M NaCl + borate buffer solution. A bias potential of 150 to 200 mV was used to localize the anodic and cathodic reactions to their respective electrodes. The noise signal was significantly affected by conditioning the electrodes at open circuit. When the electrodes were conditioned for several days, the breakdown potential increased, and the frequency and magnitude of the current transients increased. However, when the conditioning time was increased to a month, all metastable pitting transients disappeared, indicating an enhanced passive film.
- OSTI ID:
- 350129
- Report Number(s):
- CONF-980316--
- Country of Publication:
- United States
- Language:
- English
Similar Records
The effect of some fundamental aspects of the pitting corrosion of stainless steel on electrochemical noise measurements
Corrosion of 304 stainless steel exposed to nitric acid-chloride environments
Pitting corrosion monitoring with an improved electrochemical noise technique
Conference
·
Mon Dec 30 23:00:00 EST 1996
·
OSTI ID:490809
Corrosion of 304 stainless steel exposed to nitric acid-chloride environments
Book
·
Fri Aug 01 00:00:00 EDT 1997
·
OSTI ID:504793
Pitting corrosion monitoring with an improved electrochemical noise technique
Conference
·
Sun Oct 31 23:00:00 EST 1999
·
OSTI ID:696901