Engineering study of the criticality issues associated with Hanford tank 241-Z-361
Tank 241-Z-361 is associated with the Plutonium Finishing Plant (PFP). Uncertainty about the contents of the tank have led to the declaration of an Unreviewed Safety Question (USQ) and the preparation of a Justification for Continued Operation (JCO) to address flammable gas and other authorization basis issued. A Criticality Safety Team was assembled to review old data, determine its validity, and reevaluate the tank. It was concluded that the tank has a sufficient margin of safety to allow opening, sampling, and other characterizing activities. The team concluded that a criticality in Tank 241-Z-361 was extremely unlikely.
- Research Organization:
- Fluor Daniel Hanford, Inc., Richland, WA (United States)
- Sponsoring Organization:
- USDOE Office of Environmental Restoration and Waste Management, Washington, DC (United States)
- DOE Contract Number:
- AC06-96RL13200
- OSTI ID:
- 348855
- Report Number(s):
- HNF-2012; ON: DE99050430; BR: EW7002010; TRN: AHC29920%%5
- Resource Relation:
- Other Information: PBD: 22 Dec 1997
- Country of Publication:
- United States
- Language:
- English
Similar Records
Tank 241-Z-361 process and characterization history
Deep Sludge Gas Release Event Analytical Evaluation
Tank 241-Z-361 Sludge Retrieval and Treatment Alternatives
Technical Report
·
Thu Aug 06 00:00:00 EDT 1998
·
OSTI ID:348855
Deep Sludge Gas Release Event Analytical Evaluation
Conference
·
Thu Aug 15 00:00:00 EDT 2013
·
OSTI ID:348855
Tank 241-Z-361 Sludge Retrieval and Treatment Alternatives
Technical Report
·
Wed May 24 00:00:00 EDT 2000
·
OSTI ID:348855