Using high-density magnetic and electromagnetic data for waste site characterization: A case study
- Sandia National Labs., Albuquerque, NM (United States)
- New Mexico State University (United States)
Magnetometers are frequently used to characterize hazardous waste sites. Due to cost and time considerations, data are typically collected on a coarse grid with nodes on 3 to 6 meter (m) centers. Hardware and software are now available which allow the rapid and cost effective collection of information on a much finer sampling grid. In this paper we present and compare total field magnetometery data collected on 3 m centers to total field magnetometery data collected on a grid with centers of 0.5 m or less. We also compare the magnetometery data to time-domain electromagnetic (EM) data collected on a 1 m by 0.2 m grid using the recently introduced Geonics Ltd. EM61 metal detector. All three data sets were collected at an abandoned landfill radioactive Burial Site No. 11 (RB-11) is located on Kirtland Air Force Base near Albuquerque, New Mexico.
- Research Organization:
- Sandia National Labs., Albuquerque, NM (United States)
- Sponsoring Organization:
- USDOE, Washington, DC (United States)
- DOE Contract Number:
- AC04-94AL85000
- OSTI ID:
- 34456
- Report Number(s):
- SAND--95-0195C; CONF-950450--2; ON: DE95008548
- Country of Publication:
- United States
- Language:
- English