Diagnostics used in commissioning the IUCF Cooler Injector Synchrotron
- Indiana University Cyclotron Facility 2401 Milo Sampson Ln., Bloomington, Indiana 47408 (United States)
Several new diagnostics systems were designed to aid in the commissioning of the IUCF Cooler Injection Synchrotron (CIS). Among them are a time of flight measurement system (ToF), a multi-wire profile monitor system (Harp) and a beam position monitor system (BPM). Pulsed beam from the 7 MeV linear accelerator is monitored using the ToF system. Several removable Harps are mounted in the injection beamline and ring which are instrumental for tuning ring injection and accumulation. BPMs are placed at the entrance and exit of the four ring dipole magnets to facilitate beam centering during injection and ramping. Fast and slow BPM displays are available to the operator for these functions. These diagnostics and their uses for CIS ring commissioning will be discussed. {copyright} {ital 1998 American Institute of Physics.}
- Sponsoring Organization:
- USDOE
- OSTI ID:
- 344472
- Report Number(s):
- CONF-980573--
- Journal Information:
- AIP Conference Proceedings, Journal Name: AIP Conference Proceedings Journal Issue: 1 Vol. 451; ISSN 0094-243X; ISSN APCPCS
- Country of Publication:
- United States
- Language:
- English
Similar Records
Diagnostics used in commissioning the IUCF Cooler Injector Synchrotron
Beam diagnostics in the Indiana University Cooler Injector Synchrotron
Polarized beam for the IUCF cooler injector synchrotron
Journal Article
·
Wed Dec 09 23:00:00 EST 1998
· AIP Conference Proceedings
·
OSTI ID:21202397
Beam diagnostics in the Indiana University Cooler Injector Synchrotron
Journal Article
·
Tue Dec 31 23:00:00 EST 1996
· AIP Conference Proceedings
·
OSTI ID:547348
Polarized beam for the IUCF cooler injector synchrotron
Journal Article
·
Wed Dec 31 23:00:00 EST 1997
· AIP Conference Proceedings
·
OSTI ID:638725