Instrumentation and diagnostics for PEP-II
- Stanford Linear Accelerator Center Stanford University MS 17, P.O. Box 4349, Stanford, California 94309 (United States)
PEP-II is a 2.2 km-circumference collider with a 2.1 A, 3.1 GeV positron ring (the low-energy ring) 1 m above a 1 A, 9 GeV electron ring (the high-energy ring); both rings are designed to allow an upgrade to 3 A. Since June 1997, we have had three runs totaling 14 weeks to commission the full HER, reaching a current of 0.75 A. Positrons were transported through the first 90 m of the LER in January 1998, with full-ring tests planned for the summer. This workshop provides a timely opportunity to review the design of the beam diagnostics and their performance, with an emphasis on what works, what doesn{close_quote}t, and what we{close_quote}re doing to improve it. This paper discusses: the synchrotron-light monitor, including both transverse imaging onto a CCD camera and longitudinal measurements with a streak camera; beam position monitors, with processors capable of 1024-turn records, FFTs, and phase-advance measurements; tune measurements with a spectrum analyzer, including software for peak tracking; measurements of both the total ring current and the charge in each bucket, for real-time control of the fill; and beam loss monitors using small Cherenkov detectors for measuring losses from both stored and injected beam. {copyright} {ital 1998 American Institute of Physics.}
- Research Organization:
- Lawrence Berkeley National Laboratory
- Sponsoring Organization:
- USDOE
- DOE Contract Number:
- AC03-76SF00098; AC03-76SF00515
- OSTI ID:
- 344454
- Report Number(s):
- CONF-980573--
- Journal Information:
- AIP Conference Proceedings, Journal Name: AIP Conference Proceedings Journal Issue: 1 Vol. 451; ISSN APCPCS; ISSN 0094-243X
- Country of Publication:
- United States
- Language:
- English
Similar Records
Instrumentation and diagnostics for PEP-II
Instrumentation and diagnostics for PEP-II
Commissioning the beam diagnostics for the PEP-II B Factory
Journal Article
·
Wed Dec 09 23:00:00 EST 1998
· AIP Conference Proceedings
·
OSTI ID:21202423
Instrumentation and diagnostics for PEP-II
Conference
·
Fri May 01 00:00:00 EDT 1998
·
OSTI ID:666109
Commissioning the beam diagnostics for the PEP-II B Factory
Conference
·
Mon Jun 01 00:00:00 EDT 1998
·
OSTI ID:666111