Minimum bar size for flexure testing of irradiated SiC/SiC composite

Technical Report ·
DOI:https://doi.org/10.2172/335386· OSTI ID:335386
;  [1]
  1. Pacific Northwest National Lab., Richland, WA (United States)
This report covers material presented at the IEA/Jupiter Joint International Workshop on SiC/SiC Composites for Fusion structural Applications held in conjunction with ICFRM-8, Sendai, Japan, Oct. 23-24, 1997. The minimum bar size for 4-point flexure testing of SiC/SiC composite recommended by PNNL for irradiation effects studies is 30 {times} 6 {times} 2 mm{sup 3} with a span-to-depth ratio of 10/1.
Research Organization:
Oak Ridge National Lab., TN (United States)
Sponsoring Organization:
USDOE, Washington, DC (United States)
DOE Contract Number:
AC06-76RL01830
OSTI ID:
335386
Report Number(s):
DOE/ER--0313/23; ON: DE98004697