Air movement is one of the six main variables determining human thermal comfort; air temperature, relative humidity, mean radiant temperature, metabolic rate, and clothing insulation are the others. Recently, HVAC design innovations, energy conservation concerns, and new laboratory data on fan cooling and drafts have brought substantial attention to the issue of acceptable levels of air movement in office environments. Thermal comfort standards for indoor occupancy include air movement limits that are constructed from often conflicting evidence and are frequently difficult to apply. A primary reason is that, while air movement can provide desirable cooling in ``warm`` conditions, it can also increase the risk of unacceptably cool drafts. The transition zone from desirable cooling to uncomfortable draft is a complicated function of physics, physiology, and human expectation. This work focuses on air movement for cooling in the expected temperature range, 25.5 C to 28.5 C of this transition zone. Fifty-four human subjects were given control of the air supply velocity from a desk fan (FAN), a floor-mounted diffuser (FMD), and a desk-mounted diffuser (DMD) at a single ambient air temperature. The subjects were asked to adjust the air movement as they pleased to make themselves comfortable. These tests encompassed the full temperature range of the ``transition zone,`` 25.5 C to 28.5 C. Physical measurements of the environment were made and subjective votes collected, including thermal sensation, thermal preference, work area preferences, personal control preferences, and health characteristics. A model that predicts the percentage of satisfied people (the PS model) as a function of air temperature and air movement in warm conditions is proposed.
- OSTI ID:
- 33304
- Report Number(s):
- CONF-9406105--
- Country of Publication:
- United States
- Language:
- English
Similar Records
Hot, cold, or just right? An infrared biometric sensor to improve occupant comfort and reduce overcooling in buildings via closed-loop control
Air movement and thermal comfort
Thermal comfort in transitional spaces in the cool season of Bangkok
Journal Article
·
Tue Mar 05 19:00:00 EST 2024
· Energy and Buildings
·
OSTI ID:2407291
Air movement and thermal comfort
Journal Article
·
Sun Aug 01 00:00:00 EDT 1993
· ASHRAE Journal (American Society of Heating, Refrigerating and Air-Conditioning Engineers); (United States)
·
OSTI ID:5795670
Thermal comfort in transitional spaces in the cool season of Bangkok
Conference
·
Thu Oct 01 00:00:00 EDT 1998
·
OSTI ID:649447