Heat transfer and flow characteristics of automotive brazed aluminum heat exchangers

Conference ·
OSTI ID:33284
; ;  [1]
  1. Industrial Technology Research Inst., Hsinchu (Taiwan, Province of China). Energy and Research Labs.

Extensive experiments on the heat transfer and pressure-drop characteristics of automotive brazed aluminum heat exchangers were carried out. In the present study, 18 samples of louvered-fin heat exchangers with different geometrical parameters, including tube width, louver length, louver pitch, fin height, and fin pitch, were tested in an induced open wind tunnel. Results are presented as plots of friction factor and Colburn j-factor against Reynolds number based on the volumetric hydraulic diameter in the range of 200 to 1,600. The comparisons between the Sahnoun and Webb model and the present test data are reported and good agreement was found. By introducing a finning factor, a simpler correlation of the Colburn j-factor is obtained. The heat transfer data for the Colburn j-factor are correlated within 10%, and those for the friction factor are within 15%.

OSTI ID:
33284
Report Number(s):
CONF-9406105--
Country of Publication:
United States
Language:
English

Similar Records

Air side performance of convex-louver fin heat exchangers
Book · Sat Dec 30 23:00:00 EST 1995 · OSTI ID:455388

Experimental study of heat transfer and flow friction characteristics of automotive evaporators
Conference · Fri Dec 30 23:00:00 EST 1994 · OSTI ID:33277

Determination of heat transfer and friction characteristics of an adapted inclined louvered fin
Journal Article · Tue Feb 28 23:00:00 EST 2006 · Experimental Thermal and Fluid Science · OSTI ID:20711983