skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Decontamination and dismantlement of the old hot laundry, CFA-669. Final report

Technical Report ·
DOI:https://doi.org/10.2172/33080· OSTI ID:33080

This final report describes the decontamination and dismantlement (D&D) of the old hot laundry, located at the Idaho National Engineering Laboratory (INEL) Central Facilities Area (CFA). The report describes the site before and after D&D, processes used, cost and duration, and waste volume generated. In addition, lessons learned are presented. Pre-D&D characterization indicated gross alpha concentrations in the building ranged from 6 to 310 pCi/g and gross beta measurements from 6 to 15,000 pCi/g. Gamma spectrum analysis identified cobalt-60, cesium-137, antimony-125, europium-152, europium-154, and niobium-94.

Research Organization:
Lockheed Idaho Technologies Co., Idaho Falls, ID (United States)
Sponsoring Organization:
USDOE, Washington, DC (United States)
DOE Contract Number:
AC07-94ID13223
OSTI ID:
33080
Report Number(s):
INEL-94/0139; ON: DE95008672; TRN: 95:008984
Resource Relation:
Other Information: PBD: Jan 1995
Country of Publication:
United States
Language:
English