Waste compatibility and final report for Tank 241-A-101, Grab Samples 1A-96-1, 1A-96-2, and 1A-96-3
This document is the final report deliverable for tank 241-A- 101 grab samples. Three grab samples (IA-96-1, IA-96-2 and IA-96-3) were taken from riser 4 of tank 241-A-101. Samples were collected on April 3, 1996 and received by the 222-S Laboratory on April 4, 1996. Analyses were performed in accordance with the Compatibility Grab Sampling and Analysis Plan (TSAP) and the Data Quality Objectives for Tank Farms Waste Compatibility Program (DQO). The samples were subsampled and analyzed in accordance with the TSAP. Two of the three grab samples contained a significant amount of solids and special analyses were requested. None of the samples exceeded notification limits. No similarities in sample appearance were noted; this could be an explanation for the varying analytical results. Quality control issues are discussed in each analytical subheading. The raw data for all analyses are included in this report.
- Research Organization:
- Westinghouse Hanford Co., Richland, WA (United States)
- Sponsoring Organization:
- USDOE Office of Environmental Restoration and Waste Management, Washington, DC (United States)
- DOE Contract Number:
- AC06-96RL13200
- OSTI ID:
- 326829
- Report Number(s):
- WHC-SD-WM-DP--186; ON: DE98057637; BR: EW3120074
- Country of Publication:
- United States
- Language:
- English
Similar Records
Tank 241-AP-106, grab samples, 6AP-96-1 through 6AP-96-3 analytical results for the final report
60-day waste compatibility safety issues and final results for TX-244 grab samples