Removal of fusain with a small-diameter H.M. cyclone operating with ultrafine medium particles
- Coal Preparation Research Inst., Tangshan (China)
As evidenced by study of physio-chemical property and liberation characteristics of the macerals of Shenfu young coal, the vitrain differs slightly with fusain in density, with the density of the former being about 0.1g/l higher. After being crushed to {minus}0.5mm, the individual maceral can be liberated, and the fusainite content in the {minus}0.043mm size fraction is noticeably higher than that in the 0.5--0.043mm size fraction. Based on the theory and practical cleaning result obtained through using a small-diameter cyclone for efficient cleaning of fine coal according to density, tests on the removal of fusain from 0.5--0.043mm size coal were conducted with a small-size cyclone operating with ultrafine medium. The test proved to be successful, with a fusain removal rate of up to 50%.
- OSTI ID:
- 324831
- Report Number(s):
- CONF-970931-; TRN: IM9911%%528
- Resource Relation:
- Conference: 14. annual international Pittsburgh coal conference and workshop: clean coal technology and coal utilization, Taiyuan (China), 23-27 Sep 1997; Other Information: PBD: 1997; Related Information: Is Part Of Fourteenth annual international Pittsburgh coal conference and workshop: Proceedings; PB: [1500] p.