Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Annular flow of R-134a through a high aspect ratio duct: Local void fraction, droplet velocity and droplet size measurements

Technical Report ·
DOI:https://doi.org/10.2172/304179· OSTI ID:304179
; ;  [1]
  1. Lockheed Martin Corp., Schenectady, NY (United States)

Local measurements were made in annular flow of R-134a through a vertical duct. Using a gamma densitometer, hot-film anemometer and laser Doppler velocimeter, profiles of void fraction, liquid droplet frequency and droplet velocity were acquired across the narrow test section dimension. Based upon these results, data for liquid droplet size were obtained and compared to previous experimental results from the literature. These data are useful for developing an improved understanding of practical two-phase refrigerant flows, and for assessment of advanced two-fluid computer codes.

Research Organization:
Knolls Atomic Power Lab., Schenectady, NY (United States)
Sponsoring Organization:
USDOE Assistant Secretary for Nuclear Energy, Washington, DC (United States)
DOE Contract Number:
AC12-76SN00052
OSTI ID:
304179
Report Number(s):
KAPL-P--000071; K--98042; CONF-981107--; ON: DE99001457
Country of Publication:
United States
Language:
English

Similar Records

Experimental study of dispersed droplets in high-pressure annular flows
Journal Article · Sun Oct 31 23:00:00 EST 1999 · Journal of Heat Transfer · OSTI ID:20005630

High pressure annular two-phase flow in a narrow duct. Part 1: Local measurements in the droplet field, and Part 2: Three-field modeling
Technical Report · Thu Jul 01 00:00:00 EDT 1999 · OSTI ID:353192

Interfacial shear modeling in two-phase annular flow
Conference · Thu Oct 31 23:00:00 EST 1996 · OSTI ID:350926