Real-time system for respiratory-cardiac gating in positron tomography
Journal Article
·
· IEEE Transactions on Nuclear Science
- Lawrence Berkeley National Lab., CA (United States). Center for Functional Imaging
- CTI, Inc., Knoxville, TN (United States)
A Macintosh-based signal processing system has been developed to support simultaneous respiratory and cardiac gating on the ECAT EXACT HR PET scanner. Using the Lab-View real-time software environment, the system reads analog inputs from a pneumatic respiratory bellows and an EGG monitor to compute an appropriate histogram memory location for the PET data. Respiratory state is determined by the bellows signal amplitude; cardiac state is based on the time since the last R-wave. These two states are used in a 2D lookup table to determine a combined respiratory-cardiac state. A 4-bit address encoding the selected histogram is directed from the system to the ECAT scanner, which dynamically switches the destination of tomograph events as respiratory-cardiac state changes. to Test the switching efficiency of the combined Macintosh/ECAT system, a rotating emission phantom was built. Acquisitions with 25 msec states while the phantom was rotating at 240 rpm demonstrate the system could effectively stop motion at this rate, with approximately 5 msec switching time between states.
- Sponsoring Organization:
- Department of Health and Human Services, Washington, DC (United States); USDOE Office of Energy Research, Washington, DC (United States)
- DOE Contract Number:
- AC03-76SF00098
- OSTI ID:
- 292928
- Report Number(s):
- CONF-971147--
- Journal Information:
- IEEE Transactions on Nuclear Science, Journal Name: IEEE Transactions on Nuclear Science Journal Issue: 4Pt2 Vol. 45; ISSN 0018-9499; ISSN IETNAE
- Country of Publication:
- United States
- Language:
- English
Similar Records
Acquisition and automated 3-D segmentation of respiratory/cardiac-gated PET transmission images
Respiratory compensation in cardiac PET using doubly-gated acquisitions
Compensation for respiratory motion in cardiac PET - A feasibility study
Conference
·
Mon Dec 30 23:00:00 EST 1996
·
OSTI ID:513210
Respiratory compensation in cardiac PET using doubly-gated acquisitions
Journal Article
·
Thu May 01 00:00:00 EDT 1997
· Journal of Nuclear Medicine
·
OSTI ID:563341
Compensation for respiratory motion in cardiac PET - A feasibility study
Journal Article
·
Wed May 01 00:00:00 EDT 1996
· Journal of Nuclear Medicine
·
OSTI ID:447768