The performance of the DELPHI hadron calorimeter at LEP

Journal Article · · IEEE Transactions on Nuclear Science
DOI:https://doi.org/10.1109/23.507216· OSTI ID:276494
;  [1];  [2]
  1. Inst. for High Energy Physics, Protvino (Russian Federation)
  2. FZU, Praha (Czech Republic). Inst. of Physics

The DELPHI Hadron Calorimeter was conceived more than ten years ago, as an instrument to measure the energy of hadrons and hadronic jets from e{sup +}e{sup {minus}} collisions at the CERN collider LEP. In addition it was expected to provide a certain degree of discrimination between pions and muons. The detector is a rather simple and relatively inexpensive device consisting of around 20,000 limited streamer plastic tubes, with inductive pad read-out, embedded in the iron yoke of the 1.2 T DELPHI magnet. Its depth is at minimum 6.6 nuclear interaction lengths. The electronics necessary for the pad readout was designed to have an adequate performance for a reasonable cost. This detector has proved over six years of operation to have an entirely satisfactory performance and great reliability; for example less than 1% of the streamer tubes have failed and electronic problems remain at the per mil level. During the past two years an improvement program has been under way. It has been found possible to use the streamer tubes as strips, hence giving better granularity and particle tracking, by reading out the cathode of individual tubes. The constraints on this were considerable because of the inaccessibility of the detectors in the magnet yoke. However, a cheap and feasible solution has been found. The cathode readout leads to an improved energy resolution, better {mu} identification, a better {pi}/{mu} separation and to possibilities of neutral particle separation. The simultaneous anode read-out of several planes of the endcaps of the detector will provide a fast trigger in the forward/backward direction which is an important improvement for LEP200. On the barrel the system will provide a cosmic trigger which is very useful for calibration as counting rates at LEP200 will be very low.

OSTI ID:
276494
Report Number(s):
CONF-951073--
Journal Information:
IEEE Transactions on Nuclear Science, Journal Name: IEEE Transactions on Nuclear Science Journal Issue: 3Pt2 Vol. 43; ISSN 0018-9499; ISSN IETNAE
Country of Publication:
United States
Language:
English

Similar Records

The cathode read-out of the DELPHI hadron calorimeter
Journal Article · Tue Aug 01 00:00:00 EDT 1995 · IEEE Transactions on Nuclear Science · OSTI ID:129172

Design and performance of a CCD based readout for the DELPHI barrel electromagnetic calorimeter
Conference · Fri Jan 31 23:00:00 EST 1986 · IEEE Trans. Nucl. Sci.; (United States) · OSTI ID:6030865

Thin gap gas chambers for the DELPHI endcaps
Conference · Mon Dec 30 23:00:00 EST 1996 · OSTI ID:512984