Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

High resolution x-ray sensor for nondestructive evaluation

Journal Article · · IEEE Transactions on Nuclear Science
DOI:https://doi.org/10.1109/23.507103· OSTI ID:276439
; ; ;  [1];  [2]
  1. Radiation Monitoring Devices, Inc., Watertown, MA (United States)
  2. Scientific Measurement Systems, Inc., Austin, TX (United States)

Nondestructive evaluation (NDE) using X-rays is becoming indispensable for detecting microdefects in new materials currently used in aerospace and other engineering disciplines. Existing X-ray sensors pose limitations on the speed of operation due to persistence of the sensor and a problematic tradeoff between the sensor thickness and spatial resolution. To address these limitations the authors are developing a large area structured CsI(Tl) imaging sensor for NDE using CCD based radiographic and computed tomographic systems. The sensor is formed by vapor deposition of CsI(Tl) onto a specially designed fiberoptic substrate. The work has produced X-ray sensors with a factor of 4.5 greater light output, at least three orders of magnitude faster decay time response, and greater spatial resolution (16% modulation transfer function, MTF(f), at 14 linepairs per millimeter (lp/mm)) compared to the currently used high density Tb{sub 2}O{sub 3} doped fiberoptic glass scintillators. These performance advances will address the limitations of existing detector technology by producing high quality images and fast scan times required for real-time NDE inspection. Performance measurements for prototype CsI(Tl) scintillator converters are presented. With these new sensors the development of larger area fiberoptic taper based CCD detectors with millisecond data acquisition capabilities and high spatial resolution suitable for NDE applications will be possible.

OSTI ID:
276439
Report Number(s):
CONF-951073--
Journal Information:
IEEE Transactions on Nuclear Science, Journal Name: IEEE Transactions on Nuclear Science Journal Issue: 3Pt2 Vol. 43; ISSN 0018-9499; ISSN IETNAE
Country of Publication:
United States
Language:
English

Similar Records

CCD-based high resolution digital radiography system for non destructive evaluation
Conference · Mon Dec 30 23:00:00 EST 1996 · OSTI ID:512979

High speed x-ray imaging camera using a structured CsI(Tl) scintillator
Journal Article · Tue Jun 01 00:00:00 EDT 1999 · IEEE Transactions on Nuclear Science · OSTI ID:679561

High-resolution x-ray imaging using a structured scintillator
Journal Article · Sun Feb 14 23:00:00 EST 2016 · Medical Physics · OSTI ID:22579847