Analysis of the 241SY101 pump removal trailer and the 241SY101 strongback

Technical Report ·
DOI:https://doi.org/10.2172/273268· OSTI ID:273268
The purpose of the calculations contained in the attached appendix is to determine the vibrational stability of the following combination (The Combination); shipping container, strongback and trailer. The vibrational stability of The Combination will be determined with the shipping container and strongback in the upright position. If the natural frequency of The Combination coincides with the input frequency and no damping is present, resonance will occur. The result of this is that the natural frequency of the Combination must be calculated as well as the input frequency. The input frequency in this case is caused by wind. Due to their geometrical complexity the upper and lower hydraulic clevises were analyzed for structural adequacy by using finite-element analysis (FEA). The FEA software COSMOS/M version 1.70 was used to model the upper and lower hydraulic clevis. All designs are in accordance with Standard Architectural-Civil Design Criteria, Design Loads for Facilities (DOE-RL 1989) and are safety class 3. The design and fabrication of each component is in accordance with American Institute of Steel Construction, Manual of Steel Construction, (AISC, 1989). The analyses contained in this document reflects the as-built condition of the 241SY101 hydraulic trailer.
Research Organization:
Westinghouse Hanford Co., Richland, WA (United States)
Sponsoring Organization:
USDOE, Washington, DC (United States)
DOE Contract Number:
AC06-87RL10930
OSTI ID:
273268
Report Number(s):
WHC-SD-WM-DA--194; ON: DE96050106
Country of Publication:
United States
Language:
English