A study of passive safety features by utilizing intra-subassembly-equipped self-actuated shutdown mechanism for future large fast breeder reactors
- Power Reactor and Nuclear Fuel Development Corp., Oarai, Ibaraki (Japan)
Passive prevention of core disruptive accidents (CDAs) is desired in terms of enhancement of safety for future fast breeder reactors. In addition, mitigation of CDA`s consequences should be required because mitigation measures have a potential of applying to all accidents, while prevention measures are prepared for specific accident initiators. In this paper, the Intra-Subassembly-equipped Self-Actuated Shutdown System (IS-SASS) , which is considered effective on passive prevention and mitigation of CDAs, is described. The IS-SASS is introduced in a fuel subassembly and consists of absorber materials at the top of the active core and an inner duct through which molten fuel can be excluded out of the core. The determination of the appropriate number of the IS-SASS units, their arrangement in the core and their suitable structure are found to be suited to prevention and mitigation of CDAs for liquid metal-cooled large fast breeder reactors.
- OSTI ID:
- 271923
- Report Number(s):
- CONF-960306-; ISBN 0-7918-1226-X; TRN: 96:017231
- Resource Relation:
- Conference: ICONE 4: ASME/JSME international conference on nuclear engineering, New Orleans, LA (United States), 10-13 Mar 1996; Other Information: PBD: 1996; Related Information: Is Part Of ICONE-4: Proceedings. Volume 1 -- Part B: Basic technological advances; Rao, A.S. [ed.] [General Electric Nuclear Energy, San Jose, CA (United States)]; Duffey, R.B. [ed.] [Brookhaven National Lab., Upton, NY (United States)]; Elias, D. [ed.] [Commonwealth Edison, Downers Grove, IL (United States)]; PB: 564 p.
- Country of Publication:
- United States
- Language:
- English
Similar Records
Development of Self-Actuated Shutdown Systems for LMFBR Plants (Final Report)
Self-actuated shutdown system for a commercial size LMFBR. Final report