The first PANDA tests
- Paul Scherrer Inst., Villigen (Switzerland). Thermal-Hydraulics Lab.
The PANDA test facility at PSI in Switzerland is used to study the long-term Simplified Boiling Water Reactor (SBWR) Passive Containment Cooling System (PCCS) performance. The PANDA tests demonstrate performance on a larger scale than previous tests and examine the effects of any non-uniform spatial distributions of steam and non-condensables in the system. The PANDA facility has a 1:1 vertical scale, and 1:25 ``system`` scale (volume, power, etc.). Steady-state PCCS condenser performance tests and extensive facility characterization tests have been completed. Transient system behavior tests were conducted late in 1995; results from the first three transient tests (M3 series) are reviewed. The first PANDA tests showed that the overall global behavior of the SBWR containment was globally repeatable and very favorable; the system exhibited great ``robustness.``
- OSTI ID:
- 271921
- Report Number(s):
- CONF-960306--; ISBN 0-7918-1226-X
- Country of Publication:
- United States
- Language:
- English
Similar Records
New PANDA Tests to Investigate Effects of Light Gases on Passive Safety Systems
SBWR design update: Passively safe, nuclear power generation for the twenty first century