Results from the NRC AP600 testing program at the Oregon State University APEX facility
- Oregon State Univ., Corvallis, OR (United States)
- Nuclear regulatory Systems, Washington, DC (United States)
- Univ. of Maryland, College Park, MD (United States)
The Department of Nuclear Engineering at Oregon State University (OSU) is performing a series of confirmatory tests for the U.S. Nuclear Regulatory Commission. These tests are being conducted in the Advanced Plant Experiment (APEX) facility which is a 1/4 length scale and 1/192 volume scale integral system simulation of the Westinghouse Advanced Passive 600 MWe (AP600) plant. The purpose of the testing program is to examine AP600 passive safety system performance, particularly during long term cooling. Thus far, OSU has successfully performed ten integral system tests for the NRC. This paper presents a description of the APEX facility and summarizes the important results of the NRC test program at OSU.
- Research Organization:
- Nuclear Regulatory Commission, Washington, DC (United States). Office of Nuclear Regulatory Research; Brookhaven National Lab., Upton, NY (United States)
- OSTI ID:
- 269713
- Report Number(s):
- NUREG/CP--0149-Vol.1; CONF-9510156--Vol.1; ON: TI96009154
- Country of Publication:
- United States
- Language:
- English
Similar Records
Description of the OSU APEX test facility to assess AP600 passive safety
Comparison of SPES-2 and APEX tests to examine AP600 integral system performance
Information on the Advanced Plant Experiment (APEX) Test Facility
Journal Article
·
Sat Dec 30 23:00:00 EST 1995
· Transactions of the American Nuclear Society
·
OSTI ID:411823
Comparison of SPES-2 and APEX tests to examine AP600 integral system performance
Conference
·
Sat Dec 30 23:00:00 EST 1995
·
OSTI ID:225229
Information on the Advanced Plant Experiment (APEX) Test Facility
Technical Report
·
Fri May 01 00:00:00 EDT 2015
·
OSTI ID:1369620