Results of Parametric Design Studies of MOX Lead Test Assembly
- ORNL
The parametric studies of MOX LTA design have been executed to choose plutonium content in assembly zones for two options of MOX LTA: 3-zones and Island. For 3-zones (100% Plutonium) MOX LTA the fissile plutonium content composition of 4.2%/3,0%/2% has been chosen. MOX LTA of the chosen compositions has been studied by using multi-assembly configuration that allows investigating of influence of MOX LTA environment: uranium assemblies of different irradiation. Plutonium Island with 54 plutonium pins in the center of MOX LTA has been considered in two modifications: uniform island; and graded island with lower plutonium content in one peripheral row of pins. It is shown that plutonium content in the uniform island cannot exceed 2.7% because of adopted power peaking limitations and therefore this design seems unreasonable for practical use. For graded island the plutonium content composition 3.8%/2.8% with uranium environment of 3.7% U-235 has been chosen. Evolution of assembly power and burnup distributions, inter-pin power and isotopic distributions while fuel irradiating have been analyzed. In addition to the base uranium environment of 3.7%, a set of calculations has been executed for 4.4%. Most of the studies have been executed by the code TVS-M that is at the final stage of licensing and it is to be used in the nearest future as a base instrument for VVER core calculations while using both uranium and MOX fuel. So the obtained results must be considered as preliminary ones and they demand additional analysis and investigations.
- Research Organization:
- Oak Ridge National Lab., TN (US)
- Sponsoring Organization:
- USDOE Office of Fissile Materials Disposition (MD) (US)
- DOE Contract Number:
- AC05-96OR22464
- OSTI ID:
- 2690
- Report Number(s):
- ORNL/SUB/98-85B99398V-1
- Country of Publication:
- United States
- Language:
- English
Similar Records
Kinetics Parameters of VVER-1000 Core with 3 MOX Lead Test Assemblies To Be Used for Accident Analysis Codes
PU Disposition in Russian VVERs: Physics Studies of Lead Test Assembly Design
Design Studies of ``100% Pu'' Mox Lead Test Assembly
Technical Report
·
Tue Mar 07 23:00:00 EST 2000
·
OSTI ID:814131
PU Disposition in Russian VVERs: Physics Studies of Lead Test Assembly Design
Conference
·
Sun May 07 00:00:00 EDT 2000
·
OSTI ID:771483
Design Studies of ``100% Pu'' Mox Lead Test Assembly
Technical Report
·
Wed Jan 10 23:00:00 EST 2001
·
OSTI ID:777711