Probability of ignition of reactive wastes by rotary sampling drills
Sampling with a rotary drill could potentially cause a fire in some Hanford tanks. If the rotary drill experiences a failure while in fuel-rich, dry waste, the waste could be ignited by the hot drill bit. For the saltcake tanks subject to this hazard, this report presents a methodology for calculating the probabilities of fire due to core drill failure. The methodology utilizes sampling data from tank characterization studies to determine the amount of reactive waste in the tanks.
- Research Organization:
- Pacific Northwest Lab., Richland, WA (United States)
- Sponsoring Organization:
- USDOE, Washington, DC (United States)
- DOE Contract Number:
- AC06-76RL01830
- OSTI ID:
- 263928
- Report Number(s):
- PNNL--11222; ON: DE96013198
- Country of Publication:
- United States
- Language:
- English
Similar Records
Calculation of the proportion of reactive waste for hydrogen ignition scenario
Ignitability testing for core drilling system. Final report
National emission standards for hazardous air pollutants application for approval to construct rotary mode core-sampling truck and exhauster