3-D analysis of current distribution and AC loss induced by external AC magnetic field in multifilamentary superconducting wires

Journal Article · · IEEE Transactions on Magnetics
DOI:https://doi.org/10.1109/20.497444· OSTI ID:260598
 [1]; ;  [2]
  1. Japan Research Inst., Ltd., Osaka (Japan). Dept. of Engineering Systems
  2. Tokyo Electric Power, Ltd., Yokohama (Japan). Power Engineering R and D Center

Using the nodal element method and A-{phi} formulation, the AC loss of a high-Tc multifilamentary superconducting wire in external AC magnetic field is analyzed and compared with experimental results. This formulation is effective for convergence. Current distribution and magnetic field are consistent with the Bean model, and the numerical AC loss is in good agreement with the experiments.

OSTI ID:
260598
Report Number(s):
CONF-9507112--
Journal Information:
IEEE Transactions on Magnetics, Journal Name: IEEE Transactions on Magnetics Journal Issue: 3Pt1 Vol. 32; ISSN IEMGAQ; ISSN 0018-9464
Country of Publication:
United States
Language:
English

Similar Records

AC current distribution and losses in multifilamentary superconductors exposed to longitudinal magnetic field
Journal Article · Mon Jul 01 00:00:00 EDT 1996 · IEEE Transactions on Magnetics · OSTI ID:367678

Dependence of magnetic instability of AC superconducting wire on phases of external AC magnetic field
Journal Article · Mon Jul 01 00:00:00 EDT 1996 · IEEE Transactions on Magnetics · OSTI ID:287723

Dependence of self field AC losses in AC multifilamentary composites and cables on external AC magnetic field
Journal Article · Sun Jun 01 00:00:00 EDT 1997 · Advances in Cryogenic Engineering · OSTI ID:482139