Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

The motional Stark effect diagnostic for ITER (in EN)

Journal Article · · Review of Scientific Instruments
DOI:https://doi.org/10.1063/5.0215575· OSTI ID:2582171

An overview of the plans for the motional Stark effect (MSE) diagnostic installation on the International Thermonuclear Experimental Reactor (ITER) is presented. The MSE diagnostic uniquely provides spatially localized magnetic field measurements inside the plasma. These are used to constrain equilibrium reconstructions to determine q(r), the safety factor as a function of minor radius. Meeting the system requirements to deliver q-profiles and related quantities with the specified radial resolution of 20 points over the minor radius, 10 ms time resolution, and better than 10% accuracy is challenging. MSE systems observe the D/H-α emission near 656.3 nm from neutral beams. As the beam atoms traverse the magnetic field, B⃗, at high velocity, v⃗, they experience a Lorentz electric field, v⃗×B⃗, which causes the spectral emission to be split and polarized due to the Stark effect. Traditional MSE-LP (line polarization) measurements determine the direction of the magnetic field in the observation volume using polarimetric analysis of the detected light. The harsh conditions of ITER are expected to deposit thin films of contaminants on the first mirror, which would alter the polarization state of reflected light significantly. On ITER, the combination of high magnetic field strength and high energy beams makes the Stark spectrum resolution suitable for the determination of the magnetic field magnitude from the line shift, so this approach has been selected. Every aspect of the measurement system must be planned for the burning plasma environment and carefully analyzed ahead of time. Current status and plans for the system are presented.

Research Organization:
Princeton Plasma Physics Laboratory (PPPL), Princeton, NJ (United States)
Sponsoring Organization:
USDOE
Grant/Contract Number:
AC02-09CH11466
OSTI ID:
2582171
Journal Information:
Review of Scientific Instruments, Journal Name: Review of Scientific Instruments Journal Issue: 7 Vol. 95; ISSN 0034-6748
Publisher:
American Institute of Physics (AIP)Copyright Statement
Country of Publication:
United States
Language:
EN

Similar Records

Designing ITER motional Stark effect line shift (MSE-LS) spectrometers
Journal Article · Sun Jun 30 20:00:00 EDT 2024 · Review of Scientific Instruments · OSTI ID:2582172

The Motional Stark Effect Diagnostic for NSTX-U
Technical Report · Wed Jan 26 23:00:00 EST 2022 · OSTI ID:1842458

Instrumentation for a multichord motional Stark effect diagnostic in KSTAR
Journal Article · Fri Nov 14 23:00:00 EST 2014 · Review of Scientific Instruments · OSTI ID:22308614