Test results from the Department of Energy`s pressurized fluidized bed combustion hot gas cleanup program
- Dept. of Energy, Morgantown, VA (United States). Morgantown Energy Technology Center
Presented here is a summary of operations and conclusions from the last two test campaigns of the Department of Energy`s Pressurized Fluidized Bed Combustion Hot Gas Cleanup Program which was implemented by the American Electric Power Service Corporation. In these tests, the Westinghouse Advanced Particle Filter (APF) operated on a one-seventh flow from the Tidd 70-MWe Pressurized Fluidized Bed Combustor. During these tests, the filter operated as predicted with extremely high particulate removal. During the combined test periods, more than 2,800 hours of operation were accumulated--two operational periods lasted more than 650 hours. The completion of this program brings the total coal fired operating time of the APF to 5,854 hours.
- OSTI ID:
- 257066
- Report Number(s):
- CONF-950952-; TRN: IM9631%%272
- Resource Relation:
- Conference: 12. annual international Pittsburgh coal conference, Pittsburgh, PA (United States), 11-15 Sep 1995; Other Information: PBD: 1995; Related Information: Is Part Of Twelfth annual international Pittsburgh coal conference: Proceedings. Coal -- Energy and the environment; PB: 1248 p.