Measurements of plasma and fluid properties in closed cycle disk generator
Conference
·
OSTI ID:254632
- Tokyo Institute of Technology, Yokohama (Japan); and others
Plasma and fluid properties are measured in a closed cycle disk MHD generator under high enthalpy extracted conditions. Special attention is devoted to measure the exit total pressure and the Faraday current in order to estimate the isentropic efficiency and the effective Hall parameter. The maximum isentropic efficiency attained in the present experiments is 46% owing enthalpy extraction ratio of 31.6%. The maximum value of effective Hall parameter obtained in the present experiments is 2 {approximately}3 which is lower than the ideal values. It is necessary for us to make clear the reason for the lower values of the effective Hall parameter and to make effort at enhancing it in order to achieve the sufficiently high isentropic efficiency.
- OSTI ID:
- 254632
- Report Number(s):
- CONF-950697--
- Country of Publication:
- United States
- Language:
- English
Similar Records
Measurements of properties concerning isentropic efficiency in a nonequilibrium MHD disk generator
Characteristics of a disk MHD generator with inlet swirl
Demonstration of enthalpy extraction over 30% with shock-tube driven disk MHD generator
Journal Article
·
Sat Jun 01 00:00:00 EDT 1996
· IEEE Transactions on Plasma Science
·
OSTI ID:377873
Characteristics of a disk MHD generator with inlet swirl
Conference
·
Sat Dec 30 23:00:00 EST 1995
·
OSTI ID:254626
Demonstration of enthalpy extraction over 30% with shock-tube driven disk MHD generator
Conference
·
Thu Dec 30 23:00:00 EST 1993
·
OSTI ID:273302