Influence of a step-tapered undulator field on the optical pulse shape of a far-infrared free electron laser

Journal Article · · IEEE Journal of Quantum Electronics
DOI:https://doi.org/10.1109/3.502366· OSTI ID:253677
; ;  [1];  [2]
  1. FOM Inst. for Plasma Physics Rijnhuizen, Nieuwegein (Netherlands)
  2. Commissariat a l`Energie Atomique, Bruyeres-le-Chatel (France). Service de Physique et Techniques Nucleaires

The optical output of the free-electron laser for infrared experiments (FELIX), which operates in the regime of strong slippage, consists of picosecond pulses. Depending on the amount of cavity desynchronization, the optical pulse can develop substantial structure in the form of multiple subpulses. The authors present second-order autocorrelation measurements of the subpulses at several far-infrared wavelengths while applying a step-taper in the undulator field. The operation with a step-tapered undulator prevents the electrons from reabsorbing the optical field energy, leading to a smooth optical pulse. For different settings of the undulator the measured pulse shape and corresponding power spectrum are discussed. It is possible without decreasing the small-signal gain to produce a smooth high-power optical pulse during the whole saturated part of the machine pulse in an FEL oscillator with a reverse-step tapered undulator.

OSTI ID:
253677
Journal Information:
IEEE Journal of Quantum Electronics, Journal Name: IEEE Journal of Quantum Electronics Journal Issue: 6 Vol. 32; ISSN 0018-9197; ISSN IEJQA7
Country of Publication:
United States
Language:
English

Similar Records

Simulations of the TJNAF FEL with tapered and inversely tapered undulators
Journal Article · Fri Nov 30 23:00:00 EST 2001 · Nuclear Instruments and Methods in Physics Research Section A · OSTI ID:804106

A tapered undulator experiment at the ELBE far infrared hybrid-resonator oscillator free electron laser
Journal Article · Sat Jan 14 23:00:00 EST 2012 · Review of Scientific Instruments · OSTI ID:22063781

Simulations of the 100 kW TJNAF FEL Using a Step-Tapered Undulator
Journal Article · Wed May 01 00:00:00 EDT 2002 · Nuclear Instruments and Methods in Physics Research A, Vol. 483 (1-2) (2002) pp. 138-141 · OSTI ID:794941