Recovery of coincident frequency domain multiplexed detector pulses using sequential deconvolution
Journal Article
·
· Journal of Instrumentation
- North Carolina State University, Raleigh, NC (United States)
Multiplexing of radiation detector signals into a single channel significantly reduces the need for a large number of digitizer channels, which reduces the cost and the power consumption of a data acquisition system. We previously demonstrated frequency domain multiplexing by convolution using a prototype system that multiplexed two EJ-309 organic scintillators signals into a single channel. Each detector pulse was converted to a damped sinusoid which was then combined into a single channel. The combined signal was digitized and the original detector signal was recovered from the damped sinusoid by deconvolution. In this paper, we demonstrate the recovery of multiple detector signals that arrive during the same digitized record via a new sequential deconvolution method. Here, when two detectors produce signals in the same digitized record and their pulses do not overlap in time, we found that the charge, arrival time, and particle type can be estimated fairly precisely for the first pulse, but the second pulse exhibits substantial degradation in the precision of the estimated charge and arrival time. When the pulses overlap in time, we demonstrate both theoretically and experimentally that the part of the first pulse that does not overlap with the second can be recovered accurately, so the arrival time and amplitude of the first pulse can be estimated fairly precisely, but not the charge or particle type. None of these quantities can be estimated precisely for the second pulse when the two pulses overlap.
- Research Organization:
- North Carolina State University, Raleigh, NC (United States)
- Sponsoring Organization:
- USDOE National Nuclear Security Administration (NNSA), Office of Defense Nuclear Nonproliferation
- Grant/Contract Number:
- NA0002534
- OSTI ID:
- 2525943
- Alternate ID(s):
- OSTI ID: 1850335
OSTI ID: 23151847
- Journal Information:
- Journal of Instrumentation, Journal Name: Journal of Instrumentation Journal Issue: 03 Vol. 16; ISSN 1748-0221
- Publisher:
- Institute of Physics (IOP)Copyright Statement
- Country of Publication:
- United States
- Language:
- English
Similar Records
Application of deconvolution to recover frequency-domain multiplexed detector pulses
Frequency domain multiplexing of pulse mode radiation detectors
Convolution-based frequency domain multiplexing of SiPM readouts using the $\mathrm{DRS4}$ digitizer
Journal Article
·
Wed Mar 20 20:00:00 EDT 2019
· Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
·
OSTI ID:1525294
Frequency domain multiplexing of pulse mode radiation detectors
Journal Article
·
Sun Jun 17 20:00:00 EDT 2018
· Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
·
OSTI ID:1525292
Convolution-based frequency domain multiplexing of SiPM readouts using the $\mathrm{DRS4}$ digitizer
Journal Article
·
Thu Dec 16 19:00:00 EST 2021
· Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
·
OSTI ID:1977489