Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Parametric optimization of the liquid sampling-atmospheric pressure glow discharge ionization source coupled to an Orbitrap mass spectrometer for neodymium isotope ratio determinations

Journal Article · · International Journal of Mass Spectrometry

Isotope ratio determinations are a valuable tool in several application areas. In nuclear forensics, the isotope ratios of uranium and plutonium are commonly used as a signature for the nuclear material's provenance and processing history. However, signatures from other coexisting elements, such as neodymium and samarium, can offer additional insights. Here, the liquid sampling-atmospheric pressure glow discharge (LS-APGD) ionization source coupled to an Orbitrap mass spectrometer (MS) has demonstrated its utility for actinide measurements. This instrumental platform can leverage the high resolution offered by the Orbitrap MS to overcome potential isobaric interferences, such as 144Nd-144Sm, 148Nd-148Sm, and 150Nd-150Sm pairs. The work presented herein demonstrates the rapid, accurate, and precise determination of the isotope ratios for neodymium using the LS-APGD/Orbitrap MS. Both the LS-APGD and Orbitrap MS parameters were optimized systematically, with NdO+ found to be the most abundant, most reduced species after applying the optimal collision-induced dissociation modalities. A limit of detection of 3 pg of 142Nd was achieved when data was acquired and processed using the FTMS Booster, an external data acquisition and processing system offered by Spectroswiss. Excellent accuracy of better than 99 % and precision of <1 % RSD were achieved when a solution of the well-characterized neodymium standard (JNdi-1 standard) was analyzed under the optimized condition, indicating the LS-APGD/Orbitrap's great potential for isotope ratio analysis of Nd and other REEs for diverse applications.

Research Organization:
University of Florida, Gainesville, FL (United States); Oak Ridge National Laboratory (ORNL), Oak Ridge, TN (United States)
Sponsoring Organization:
USDOE National Nuclear Security Administration (NNSA), Office of Defense Nuclear Security
Grant/Contract Number:
NA0004142; AC05-00OR22725
OSTI ID:
2518993
Alternate ID(s):
OSTI ID: 3002688
Journal Information:
International Journal of Mass Spectrometry, Journal Name: International Journal of Mass Spectrometry Vol. 508; ISSN 1387-3806
Publisher:
ElsevierCopyright Statement
Country of Publication:
United States
Language:
English

References (64)

Combined atomic and molecular (CAM) ionization with the liquid sampling‐atmospheric pressure glow discharge microplasma journal August 2021
Determination of uranium isotope ratios using a liquid sampling atmospheric pressure glow discharge/Orbitrap mass spectrometer system journal August 2017
Complete resolution across the neodymium/samarium isotopic envelope with a liquid sampling‐atmospheric pressure glow discharge — Orbitrap mass spectrometer journal September 2024
TIMS versus multicollector-ICP-MS: coexistence or struggle for survival? journal January 2004
Liquid sampling–atmospheric pressure glow discharge (LS-APGD) ionization source for elemental mass spectrometry: preliminary parametric evaluation and figures of merit journal September 2011
Ambient desorption/ionization mass spectrometry using a liquid sampling–atmospheric glow discharge (LS-APGD) ionization source journal July 2013
Evaluation of the operating parameters of the liquid sampling-atmospheric pressure glow discharge (LS-APGD) ionization source for elemental mass spectrometry journal July 2014
Characterization of arsenic species by liquid sampling-atmospheric pressure glow discharge ionization mass spectrometry journal May 2024
The use of LA-SF-ICP-MS for nuclear forensics purposes: uranium isotope ratio analysis journal August 2012
Measuring key Sm isotope ratios in irradiated UO2 for use in plutonium discrimination nuclear forensics journal April 2019
Determination of rare earth elements in uranium ores by ICP-MS after total dissolution with NH4F and matrix separation with TRU resin journal March 2023
Initial Benchmarking of the Liquid Sampling-Atmospheric Pressure Glow Discharge-Orbitrap System Against Traditional Atomic Mass Spectrometry Techniques for Nuclear Applications journal October 2018
Ultra-High Resolution Elemental/Isotopic Mass Spectrometry (m/Δm > 1,000,000): Coupling of the Liquid Sampling-Atmospheric Pressure Glow Discharge with an Orbitrap Mass Spectrometer for Applications in Biological Chemistry and Environmental Analysis journal April 2019
JNdi-1: a neodymium isotopic reference in consistency with LaJolla neodymium journal August 2000
Role of powering geometries and sheath gas composition on operation characteristics and the optical emission in the liquid sampling-atmospheric pressure glow discharge journal September 2002
Qualification of the APOLLO2.8 code package for the calculation of the fuel inventory and reactivity loss of UOx spent fuels in BWRs journal April 2009
The provenance of Australian uranium ore concentrates by elemental and isotopic analysis journal April 2008
Factors influencing the precision and accuracy of Nd isotope measurements by thermal ionization mass spectrometry journal January 2018
Nuclear forensic analysis of an unknown uranium ore concentrate sample seized in a criminal investigation in Australia journal July 2014
Molybdenum isotope fractionation in uranium oxides and during key processes of the nuclear fuel cycle: Towards a new nuclear forensic tool journal June 2020
Isotope ratio measurements of trace Nd by the total evaporation normalization (TEN) method in thermal ionization mass spectrometry journal July 2007
Enhanced Fourier transform for Orbitrap mass spectrometry journal August 2014
Roles of collisional dissociation modalities on spectral composition and isotope ratio measurement performance of the liquid sampling – atmospheric pressure glow discharge / orbitrap mass spectrometer coupling journal June 2021
Investigation of potential polyatomic interferences on uranium isotope ratio measurements for the LS-APGD-Orbitrap MS system journal January 2024
Liquid sampling-atmospheric pressure glow discharge as a secondary excitation source: Assessment of plasma characteristics journal April 2014
Development of an integrated, single electrode liquid sampling – atmospheric pressure glow discharge microplasma ionization source journal May 2021
Application of neodymium isotope ratio measurements for the origin assessment of uranium ore concentrates journal November 2014
Samarium isotope compositions of uranium ore concentrates: A novel nuclear forensic signature journal January 2021
Stable isotope techniques for verifying the declared geographical origin of food in legal cases journal March 2017
Trends and perspectives in Nuclear Forensic Science journal January 2022
An Atmospheric Pressure Glow Discharge Optical Emission Source for the Direct Sampling of Liquid Media journal July 2001
Liquid Sampling-Atmospheric Pressure Glow Discharge Ionization Source for Elemental Mass Spectrometry journal April 2011
Extraction Chromatographic Methods in the Sample Preparation Sequence for Thermal Ionization Mass Spectrometric Analysis of Plutonium Isotopes journal December 2011
Recent Advances in Nuclear Forensic Chemistry journal September 2020
Initial Characterization and Optimization of the Liquid Sampling-Atmospheric Pressure Glow Discharge Ionization Source Coupled to an Orbitrap Mass Spectrometer for the Determination of Plutonium journal July 2023
Ultrahigh-Mass Resolution Mass Spectrometry Imaging with an Orbitrap Externally Coupled to a High-Performance Data Acquisition System journal December 2023
Preliminary Assessment of Potential for Metal–Ligand Speciation in Aqueous Solution via the Liquid Sampling–Atmospheric Pressure Glow Discharge (LS-APGD) Ionization Source: Uranyl Acetate journal June 2015
Conceptual Demonstration of Ambient Desorption-Optical Emission Spectroscopy Using a Liquid Sampling-Atmospheric Pressure Glow Discharge Microplasma Source journal May 2016
Improved Uranium Isotope Ratio Analysis in Liquid Sampling–Atmospheric Pressure Glow Discharge/Orbitrap FTMS Coupling through the Use of an External Data Acquisition System journal April 2021
Nuclear forensics—a methodology providing clues on the origin of illicitly trafficked nuclear materials journal January 2005
Rapid, simultaneous separation of Sr, Pb, and Nd by extraction chromatography prior to isotope ratios determination by TIMS and MC-ICP-MS journal January 2014
Neodymium isotope ratio measurements by LC-MC-ICPMS for nuclear applications: investigation of isotopic fractionation and mass bias correction journal January 2015
Ultra-high-precision Nd-isotope measurements of geological materials by MC-ICPMS journal January 2016
Isotope ratio characteristics and sensitivity for uranium determinations using a liquid sampling-atmospheric pressure glow discharge ion source coupled to an Orbitrap mass analyzer journal January 2016
Parametric evaluation of ambient desorption optical emission spectroscopy utilizing a liquid sampling-atmospheric pressure glow discharge microplasma journal January 2017
Concomitant ion effects on isotope ratio measurements with liquid sampling – atmospheric pressure glow discharge ion source Orbitrap mass spectrometry journal January 2018
TIMS analysis of neodymium isotopes in human tooth enamel using 10 13 Ω amplifiers journal January 2017
Coupling of an atmospheric pressure microplasma ionization source with an Orbitrap Fusion Lumos Tribrid 1M mass analyzer for ultra-high resolution isotopic analysis of uranium journal January 2019
Parametric optimization and spectral line selection for liquid sampling-atmospheric pressure glow discharge – optical emission spectroscopy journal January 2019
Coupling the liquid sampling – atmospheric pressure glow discharge, a combined atomic and molecular (CAM) ionization source, to a reduced-format mass spectrometer for the analysis of diverse species journal January 2020
A multi-electrode glow discharge ionization source for atomic and molecular mass spectrometry journal January 2020
Improved uranium isotopic ratio determinations for the liquid sampling-atmospheric pressure glow discharge orbitrap mass spectrometer by use of moving average processing journal January 2022
Sensitive determination of neodymium isotope in seawater by multi-collector inductively coupled plasma mass spectrometry with ultrasound nebulization-dielectric barrier discharge vapor generation as sample introduction journal January 2024
Reference value of the JNdi-1 isotopic material without normalization journal January 2024
In situ Nd isotopic analysis of geological materials by laser ablation MC-ICP-MS journal January 2006
Precise determination of Sm, Nd concentrations and Nd isotopic compositions at the nanogram level in geological samples by thermal ionization mass spectrometry journal January 2009
High-precision and accurate determinations of neodymium isotopic compositions at nanogram levels in natural materials by MC-ICP-MS journal January 2012
Evaluation of the exothermicity of the chemi-ionization reaction Nd + O → NdO + + e and neodymium oxide, carbide, dioxide, and carbonyl cation bond energies journal April 2019
Mass Spectrometry-based Proteomics Using Q Exactive, a High-performance Benchtop Quadrupole Orbitrap Mass Spectrometer journal June 2011
Experimental Design Step by Step: A Practical Guide for Beginners journal December 2020
Origin of uranium deposits revealed by their rare earth element signature: Origin of U deposits revealed by the rare earth elements journal May 2011
Evolution of Orbitrap Mass Spectrometry Instrumentation journal July 2015
Nuclear Forensic Science: Analysis of Nuclear Material Out of Regulatory Control journal June 2016
Origin assessment of uranium ore concentrates based on their rare-earth elemental impurity pattern journal January 2010

Similar Records

Detection of Br and I as atomic anions using liquid sampling – atmospheric pressure glow discharge/Orbitrap mass spectrometry
Journal Article · Mon Sep 22 00:00:00 EDT 2025 · Journal of Analytical Atomic Spectrometry · OSTI ID:2997046