Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Uranium measurements in the field using high-resolution cadmium zinc telluride detectors

Journal Article · · Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
 [1];  [1];  [2];  [3];  [2];  [3];  [4];  [5]
  1. Pacific Northwest National Laboratory (PNNL), Richland, WA (United States)
  2. Lawrence Livermore National Laboratory (LLNL), Livermore, CA (United States)
  3. Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)
  4. Los Alamos National Laboratory (LANL), Los Alamos, NM (United States)
  5. Oak Ridge National Laboratory (ORNL), Oak Ridge, TN (United States)

A new generation of cadmium zinc telluride (CZT) detectors has become available and is being evaluated by the International Atomic Energy Agency (IAEA) for safeguards verifications in the field. The new CZT detector, model M400, is a room temperature spectrometer manufactured by H3D, Inc. The M400 demonstrates superior energy resolution, effective isotope identification capabilities, and convenient usability features when tested in a controlled laboratory environment. These characteristics define the M400 as a potential platform for IAEA field detection applications, which could become suitable for nuclear material characterization (e.g., enrichment verification) and nuclear safeguards missions. The capabilities of gamma spectrometry codes including Fixed energy, Response function Analysis with Multiple efficiencies (FRAM) from Los Alamos National Laboratory, CZT for Uranium (CZTU) from Lawrence Livermore National Laboratory, and Gamma Detector Response and Analysis Software (GADRAS) from Sandia National Laboratories were adapted for M400 spectra, and the performance of the codes has been validated. This was reported in a prior work. To further validate the performance of the high-energy resolution CZT detector and the isotopic analysis codes, a field measurement campaign consisting of uranium hexafluoride (UF6) cylinder measurements was conducted at a fuel fabrication facility. A total of 34 Type 30B cylinders containing UF6 were measured using three different M400 CZT detectors. Each detector was outfitted with a custom rectangular collimator and shield made out T-Flex®, a tungsten-impregnated polymer. Measurements were performed at three different locations of the cylinder, ensuring that the measurement geometry satisfied the infinite thickness criterion. The spectra from the M400 CZT were analyzed using the code General Enrichment Meter (GEM). For analyzing the gamma-ray spectra from UF6 cylinder, the GEM code is the appropriate tool since it relies only on the gamma-ray emissions from 235U and not from other isotopes. Results from the spectral analysis were compared with the known abundance of 235U in the cylinders, as well as with the International Target Values 2020 (ITV2020). The suitability of the different underlying techniques used by the various codes for UF6 analysis is discussed. The challenges of measuring UF6 contained in cylinders and mitigation strategies are highlighted.

Research Organization:
Pacific Northwest National Laboratory (PNNL), Richland, WA (United States)
Sponsoring Organization:
USDOE National Nuclear Security Administration (NNSA)
Grant/Contract Number:
AC05-76RL01830
OSTI ID:
2514355
Report Number(s):
PNNL-SA--190997
Journal Information:
Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment, Journal Name: Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment Vol. 1064; ISSN 0168-9002
Publisher:
ElsevierCopyright Statement
Country of Publication:
United States
Language:
English

References (2)

Thermal impacts on nondestructive analysis measurements of uranium hexafluoride journal September 2021
Gamma-ray spectrum variations for surface measurements of uranium hexafluoride cylinders
  • McFerran, Noah; Canion, Bonnie; McDonald, Benjamin
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 961 https://doi.org/10.1016/j.nima.2020.163675
journal May 2020

Similar Records

Gamma Spectrometry Code Rodeo for Uranium Enrichment—FY 2022 Report
Technical Report · Tue Feb 28 23:00:00 EST 2023 · OSTI ID:2573685

Gamma spectrometry uranium isotopic analysis rodeo: Summary of GADRAS results
Technical Report · Wed Sep 01 00:00:00 EDT 2021 · OSTI ID:1855016

Machine learning framework for predicting uranium enrichments from M400 CZT gamma spectra
Journal Article · Thu Aug 08 00:00:00 EDT 2024 · Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment · OSTI ID:2441108