Thirty-seven different elements were tested for their suitability as converter screens for direct and indirect fast neutron radiography. The use of commercial X-ray scintillator screens containing YTaO{sub 4}, LaOBr:Tm, YTaO{sub 4}:Nb, YTaO{sub 4}:Tm, CaWO{sub 4}, BaSO{sub 4}:Sr, and GdO{sub 2}S:Tb was also explored for direct fast neutron radiography. For the indirect radiographic process, only one element, holmium, was found to be better than copper. Iron was also found to work as well as copper. All other elements that were tested were inferior to copper for indirect fast neutron radiography. For direct fast neutron radiography, the results were markedly different. Copper was found to be a poor material to sue, as thirty-two of the elements performed better than the copper. Tantalum was found to be the best material to use. Several other materials that also performed remarkably well include, in order of decreasing utility, gold, lutetium, germanium, dysprosium, and thulium. Several interesting results were obtained for the commercial X-ray scintillator screens. Most notably, useful radiographs were produced with all of the various scintillation screens. However, the screens containing YTaO{sub 4}:Nb offered the greatest film densities for the shortest exposure times. Screens using GdSO{sub 4}:Tb provided the best resolution and clearest images at the sacrifice of exposure time. Also, as previous researchers found, scintillator screens offered significantly shorter exposure times than activation foils.
- Research Organization:
- Argonne National Lab., Idaho Falls, ID (United States)
- Sponsoring Organization:
- USDOE, Washington, DC (United States)
- DOE Contract Number:
- W-31109-ENG-38
- OSTI ID:
- 251361
- Report Number(s):
- ANL/ED/CP--88445; CONF-9606223--1; ON: DE96011906
- Country of Publication:
- United States
- Language:
- English
Similar Records
X-ray efficiency of phosphor screens in the 20--60 kV range
Feasibility Testing of Delayed Scintillator Screens for Indirect Digital Neutron Radiography of Irradiated Nuclear Fuel
Development of enriched boron track-etch converter screens for neutron radiographic applications
Journal Article
·
Fri Jul 15 00:00:00 EDT 1988
· J. Appl. Phys.; (United States)
·
OSTI ID:7248952
Feasibility Testing of Delayed Scintillator Screens for Indirect Digital Neutron Radiography of Irradiated Nuclear Fuel
Conference
·
Sun Nov 17 23:00:00 EST 2019
·
OSTI ID:1576753
Development of enriched boron track-etch converter screens for neutron radiographic applications
Conference
·
Sat Oct 31 23:00:00 EST 1981
·
OSTI ID:5275339