Bubble behavior and mean diameter in subcooled flow boiling

Journal Article · · Journal of Heat Transfer
DOI:https://doi.org/10.1115/1.2824023· OSTI ID:249638
 [1];  [2]
  1. Alexandria Univ. (Egypt)
  2. McMaster Univ., Hamilton (Canada)
Bubble behavior and mean bubble diameter in subcooled upward flow boiling in a vertical annular channel were investigated under low pressure and mass flux conditions. High-speed photographic results indicated that, contrary to the common understanding, bubbles tend to detach from the heating surface upstream of the net vapor generation point. Digital image processing technique was used to measure the mean bubble diameter along the subcooled flow boiling region. Data on the axial area-averaged void fraction distributions were also obtained using a single-beam gamma densitometer. Effects of the liquid subcooling, applied heat flux and mass flux on the mean bubble size were investigated. A correlation for the mean bubble diameter as a function of the local subcooling, heat flux, and mass flux was obtained. 28 refs., 8 figs., 1 tab.
Sponsoring Organization:
USDOE
OSTI ID:
249638
Journal Information:
Journal of Heat Transfer, Journal Name: Journal of Heat Transfer Journal Issue: 1 Vol. 118; ISSN 0022-1481; ISSN JHTRAO
Country of Publication:
United States
Language:
English

Similar Records

Bubble behaviour and mean diameter in subcooled flow boiling
Conference · Fri Sep 01 00:00:00 EDT 1995 · OSTI ID:111455

Void fraction measurement in subcooled forced convective boiling with refrigerant 12
Journal Article · Sun Dec 31 23:00:00 EST 1989 · Experimental Heat Transfer; (USA) · OSTI ID:6529468

Dependence of Vapor Void Fraction on Fundamental Bubble Parameters in Subcooled Flow Boiling
Conference · Sat Jul 01 00:00:00 EDT 2006 · OSTI ID:20997017