Operating experience from the Tidd PFBC hot gas clean up program
Book
·
OSTI ID:245016
- American Electric Power Service Corp., Columbus, OH (United States)
The Tidd PFBC Hot Gas Clean Up (HGCU) test facility, a $22-million project sponsored by the US Department of Energy (DOE), has accumulated over 4700 hours of coal fire operation between October 1992 and October 1994. The HGCU slip stream, which represents a 10 MWt system, utilizes a Westinghouse candle-based system to filter ash from one-seventh of the exhaust gas of the 70 MWe Tidd PFBC Demonstration Plant. This paper presents a description of the system, reviews the results of all test runs conducted during 1994, and discusses the lessons learned from this project which may be applicable in the design of commercial hot gas filtration systems.
- OSTI ID:
- 245016
- Report Number(s):
- CONF-950522--; ISBN 0-7918-1305-3
- Country of Publication:
- United States
- Language:
- English
Similar Records
Tidd hot gas clean up program. Final report
Initial operation of the Tidd PFBC HGCU test facility
Initial operation of the Tidd PFBC HGCU test facility
Technical Report
·
Sun Oct 01 00:00:00 EDT 1995
·
OSTI ID:206940
Initial operation of the Tidd PFBC HGCU test facility
Conference
·
Wed Dec 30 23:00:00 EST 1992
·
OSTI ID:10120766
Initial operation of the Tidd PFBC HGCU test facility
Conference
·
Tue Dec 31 23:00:00 EST 1991
·
OSTI ID:6971651