CFB combustor with internal solids recirculation -- Pilot testing and design applications
Conference
·
OSTI ID:245011
- Babcock and Wilcox Co., Barberton, OH (United States). Fossil Power Division
- Babcock and Wilcox Co., Alliance, OH (United States)
The new generation of B and W`s CFB boilers with entirely internal recirculation of solids collected by the primary impact separator is uniquely compact and features a simple, low-maintenance solids collection system. Thorough testing of the new concept at the Cold CFB Model and the 2.5 MWth Pilot CFB combustor confirmed its effective performance equal to that of a CFB unit with external solids recirculation from the primary separator. While providing overall advantages of compactness and simplicity, the new design is especially valuable for repowering of the existing power plants where B and W`s CFB boiler fits into the plan area of PC-fired boilers.
- OSTI ID:
- 245011
- Report Number(s):
- CONF-950522-; ISBN 0-7918-1305-3; TRN: IM9627%%377
- Resource Relation:
- Conference: 13. international conference on fluidized-bed combustion, Orlando, FL (United States), 7-10 May 1995; Other Information: PBD: 1995; Related Information: Is Part Of 13. international conference on fluidized bed combustion: Proceedings. Volume 1; Heinschel, K.J. [ed.] [Air Products and Chemicals, Inc., Allentown, PA (United States)]; PB: 719 p.
- Country of Publication:
- United States
- Language:
- English
Similar Records
GREENHOUSE GAS EMISSIONS CONTROL BY OXYGEN FIRING IN CIRCULATING FLUIDIZED BED BOILERS: PHASE II--PILOT SCALE TESTING AND UPDATED PERFORMANCE AND ECONOMICS FOR OXYGEN FIRED CFB WITH CO2 CAPTURE
Integral cylindrical cyclone and loopseal assembly for CFB combustors
Optimization of limestone sizing for CFB combustors: Results of pilot plant and bench-scale testing
Technical Report
·
Wed Oct 27 00:00:00 EDT 2004
·
OSTI ID:245011
Integral cylindrical cyclone and loopseal assembly for CFB combustors
Conference
·
Sun Dec 31 00:00:00 EST 1995
·
OSTI ID:245011
+1 more
Optimization of limestone sizing for CFB combustors: Results of pilot plant and bench-scale testing
Book
·
Sat Dec 31 00:00:00 EST 1994
·
OSTI ID:245011
+1 more
Related Subjects
01 COAL, LIGNITE, AND PEAT
20 FOSSIL-FUELED POWER PLANTS
FLUIDIZED BED BOILERS
DESIGN
PERFORMANCE
FLY ASH
RECYCLING
COAL FINES
PILOT PLANTS
FOSSIL-FUEL POWER PLANTS
RETROFITTING
PULVERIZED FUELS
COAL
FLUIDIZED-BED COMBUSTION
CIRCULATING SYSTEMS
TEST FACILITIES
OPERATION
SORBENT INJECTION PROCESSES
LIMESTONE
20 FOSSIL-FUELED POWER PLANTS
FLUIDIZED BED BOILERS
DESIGN
PERFORMANCE
FLY ASH
RECYCLING
COAL FINES
PILOT PLANTS
FOSSIL-FUEL POWER PLANTS
RETROFITTING
PULVERIZED FUELS
COAL
FLUIDIZED-BED COMBUSTION
CIRCULATING SYSTEMS
TEST FACILITIES
OPERATION
SORBENT INJECTION PROCESSES
LIMESTONE