Modeling of underground cathodic protection stray currents

Journal Article · · Corrosion
DOI:https://doi.org/10.5006/1.3292137· OSTI ID:244986
; ;  [1]
  1. Vrije Univ. Brussel, Brussels (Belgium). Dept. of Electrical Engineering
OKAPPI, a numerical model for calculating cathodic protection (CP) problems involving underground pipelines, was extended to situations involving stray currents. Aboveground structures such as rail bars, power stations, electric train or tram vehicles, and overhead lifelines were integrated in the existing model in a straightforward and transparent way. As a result, it was shown that the model can be used to deal with most of the CP problems encountered with underground pipes. Situations where the sources of stray current, such as other CP installations or earthing systems located in the soil, were modeled and compared with theory. Cases involving the four standard kinds of CP interference (anodic, cathodic, combined, and induced) were calculated and discussed. A few complex situations involving overhead systems such as trams or railways were investigated. The theoretically expected phenomena were confirmed by the calculations.
Sponsoring Organization:
USDOE
OSTI ID:
244986
Journal Information:
Corrosion, Journal Name: Corrosion Journal Issue: 6 Vol. 52; ISSN 0010-9312; ISSN CORRAK
Country of Publication:
United States
Language:
English

Similar Records

Evaluation of stray current effect on the cathodic protection of underground pipeline
Book · Mon Dec 30 23:00:00 EST 1996 · OSTI ID:427814

Fundamentals of cathodic protection interference
Journal Article · Wed Sep 01 00:00:00 EDT 1999 · Materials Performance · OSTI ID:691502

Stray current mitigation through the use of electrical isolation and cathodic protection
Journal Article · Fri Sep 01 00:00:00 EDT 1989 · Materials Performance; (USA) · OSTI ID:5281610