Improvements have been made to the timestep-size selection logic diagnostic edits of the Transient Reactor Analysis Code (TRAC), specifically to the TRAC-P version. These include both a precise account of the reason for the selection for individual timesteps and thermal-hydraulic information on mesh cells that control the timestep size. The new edits can be specified by user input as a range of timestep numbers, problem time, or both. A description of the current timestep controls in effect in TRAC-P is also given.