Calibration and Timing Performance of the Light Detection System in the ICARUS Detector
- Brookhaven
ICARUS is the largest Liquid Argon Time Projection Chamber (LArTPC) in operation and serves as the Far Detector of the Short Baseline Neutrino (SBN) program at Fermilab. It aims to investigate the possible existence of sterile neutrinos with $$\Delta m^2 \approx \SI{1}{eV^2}$$ using the Booster Neutrino Beam (BNB) and explore physics beyond the Standard Model with the Neutrinos at the Main Injector (NuMI) beam. The ICARUS light detection system, comprising 360 TPB-coated large-area Photo-Multiplier Tubes (PMTs), is crucial for triggering and event reconstruction. Due to its shallow installation, the detector is exposed to a high flux of cosmic rays, necessitating precise timing to reject background events and align neutrino interactions with the beam time profile. This talk will detail the timing inter-calibration procedures for the ICARUS light detection system, which achieve sub-nanosecond resolution. Additionally, the performance of the system in reconstructing the timing of neutrino interactions from the BNB and NuMI beams will be discussed. The results highlight the effectiveness of the ICARUS light detection system in enhancing the detector's capability for precise and reliable neutrino selection.
- Research Organization:
- Brookhaven National Laboratory (BNL), Upton, NY (United States); Fermi National Accelerator Laboratory (FNAL), Batavia, IL (United States)
- Sponsoring Organization:
- USDOE Office of Science (SC), High Energy Physics (HEP) (SC-25)
- Contributing Organization:
- ICARUS-T600
- DOE Contract Number:
- AC02-07CH11359
- OSTI ID:
- 2440223
- Report Number(s):
- FERMILAB-SLIDES-24-0228-PPD-V; oai:inspirehep.net:2826835
- Country of Publication:
- United States
- Language:
- English
Similar Records
Calibration and Timing Performance of the Light Detection System in the ICARUS Detector
Time calibration and synchronization of the scintillation light detection system in ICARUS-T600
Time calibration and synchronization of the scintillation light detection system in ICARUS-T600
Conference
·
Mon Mar 24 00:00:00 EDT 2025
·
OSTI ID:2538608
Time calibration and synchronization of the scintillation light detection system in ICARUS-T600
Conference
·
Sun Nov 19 23:00:00 EST 2023
·
OSTI ID:2217193
Time calibration and synchronization of the scintillation light detection system in ICARUS-T600
Journal Article
·
Wed Jan 17 19:00:00 EST 2024
· Journal of Instrumentation
·
OSTI ID:2246780